SPECIFICATIONS
COMPONENTS LIST
(#LKF-770) - Millivolt Board Assembly with 18” Flexible Gas Line attached**
(#BRK-770) - Millivolt Board Assembly with 18” Flexible Gas Line attached*
(#700-203) - Manual Gas Shut-off Valve
(#LKF-G900) - Refractory Set
(#BRK-500) - Log Package
(#LKF-005) - Glass Valance
(#700-15T) - Glass with Gasket
(#OCK-S0A) - LP Conversion Kit
(#600-083) - Receptacle / Speed Control Assembly with (3) Wire Nuts
(#900-085) - 4” Restrictor Plate
** Lakefield only
* Breckenridge only
1. Determine stove location, allowing for vent installation.
2. Install hearth (if applicable).
3. Complete gas line installation.
4. Complete electrical hook-up. Install any standard or optional electrical components at this time.
5. Complete venting installation.
6. Secure fireplace to flooring through holes located in unit legs. Verify all clearances at this point.
7. Install logs.
8. Install optional decorative doors or other accessories.
9. Verify proper operation of fireplace and all components.
PLACEMENT CLEARANCE REQUIREMENTS
This fireplace must be installed on a level surface capable of supporting fireplace and venting.
Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending entire depth and width of
fireplace.
Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies.
This fireplace may be installed in a bedroom.
Please be aware of the large amount of heat this fireplace will produce when determining a location.
INSTALLATION OVERVIEW
NOTE: The qualified installer should follow the procedure best suited for the installation.