![kozy heat 56150 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/kozy-heat/56150/56150_installation-manual_1999675026.webp)
4
This
optional #LKF-028 fan kit includes: -
Right & left fan assemblies - mounted
- Fan cover plate
- Temperature control switch with magnet attached
- (4) Flange nuts
- Speed Control Box with 8ft. cord
- (4) Phillips head screws (black)
OPTIONAL FAN KIT
INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
WARNING
MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.
This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged into
a properly grounded three-prong receptacle. Do not cut or remove grounding prong from plug.
NOTE
This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 Current Edition, or the Canadian electrical Code CSA C22.1.
This fan will not operate unless speed control has been turned ON and sufficient heat has been applied to temperature control switch. The fan will
turn ON and OFF automatically as fireplace heats and cools. Adjust fan to desired speed while it is running.
We recommend that an electrical outlet be installed near fireplace.
Ground
Before adjusting temperature control switch, unplug 3-prong plug on fan cord from receptacle.
Adjust position of temperature control switch to a warmer location under firebox to turn fan ON
sooner or move it to a cooler location under firebox to turn fan ON later. The fan will turn on when
sensor in temperature control switch reaches 110° F and will turn OFF when sensor reaches 90° F.
After adjustment, plug 3-prong plug on fan cord into receptacle
.
TEMPERATURE CONTROL SWITCH POSITION
Temperature Control Switch
Figure 4b
1. Locate (4) mounting studs underneath rear of fireplace.
2. Slide fan underneath fireplace, lift up, aligning (4) mount holes / slots in fan bracket to
mounting studs under firebox. Secure with (4) nuts (included).
3. Attach fan cover to back of fireplace by aligning holes in cover to holes at back of
fireplace. Secure with remaining (2) screws.
4. Mount speed control box onto left side of gas valve bracket by aligning slots in box to
holes in bracket. Secure with (2) black phillips head screws, included.
5. Place temperature control switch (magnet attached) onto bottom of firebox as close to
center as possible.
6. Plug fan cord into receptacle on speed control box.
7. Plug speed control box cord into a properly grounded three-prong receptacle.
8. Turn speed control counter-clockwise until it clicks. This is the OFF position.
9. Turn speed control ON by turning knob clockwise past click - this is the highest setting.
Figure 4a