![kozy heat 56150 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/kozy-heat/56150/56150_installation-manual_1999675015.webp)
14
1. Turn valve control knob to OFF position.
2. Shut off gas supply at manual shut off valve.
3. Disconnect flexible gas line from manual shut off valve.
4. Disconnect on/off rocker switch wires from top & bottom
terminals on valve.
5. Disconnect any remote control, wall switch or thermostat wires
from gas valve.
6. Remove glass assembly. Page 7.
7. Remove log set and set aside where they will not be broken.
8. Remove burner cover by lifting front of cover up and to the right.
9. Remove (7) nuts securing board. Lift board up and out of firebox.
1. Place board in firebox, aligning holes in control board to mounting
studs. MAKE SURE SEALING GASKET IS IN PLACE ON
FIREBOX BOTTOM! Secure with nuts previously removed.
2. Reinstall burner cover, making sure burner tube is properly
positioned over burner orifice and sides of cover are inside
flanges on board.
3. Re-connect flexible gas line to manual shut off valve.
4. Reconnect any remote control, wall switch or thermostat wires
to top & bottom terminals on gas valve.
5. Re-install log set. Page 13.
6. Re-install glass assembly. Page 7.
7. Verify proper log placement, operation of fireplace, and any
electrical components.
MILLIVOLT BOARD REMOVAL & INSTALLATION
REMOVAL
INSTALLATION
RE-CONNECT ANY REMOTE /
THERMOSTAT WIRES
Figure 14a
CAUTION
CHECK ALL CONNECTIONS FOR LEAKS WITH SOAPY
WATER, WHETHER FIELD OR FACTORY MADE.
WARNING
DO NOT OPERATE FIREPLACE WITHOUT SEALING
GASKET (LOCATED UNDER MILLIVOLT BOARD) IN
PLACE. IF GASKETING IS DAMAGED, IT MUST BE
REPLACED.
CAUTION
If burner and/or pilot have been burning, use
appropriate protection to avoid burns or damage to
personal property before removing any components.