SAFETY INFORMATION                           

 

 

Installation  and  repair  should  be  done  only  by  a  qualified  service  person.  The  appliance  should  be  inspected  by  a  
qualified service person before use. Annual inspection by a qualified service person is required to maintain warranty. 
More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative 
that  control  compartments,  burners  and  circulation  air  passageways  of  the  appliance  be  kept  clean. 

 

If  this  appliance  is  installed  directly  on  carpeting,  tile  or  other  combustible  material  other  than  wood  flooring,  the  
appliance  shall  be  installed  on  a  metal  or  wood  panel  extending  the  full  width  and  depth  of  the  appliance. 

 

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns 
or clothing ignition.  

 

Young  children  should  be  carefully  supervised  when  they  are  in  the  same  room  as  the  appliance.  Toddlers,  young  
children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at 
risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, 
young children and other at risk individuals out of the room and away from hot surfaces.   

 

Clothing or other flammable material should not be placed on or near the appliance. 

 

Adequate accessibility clearances for servicing and proper operation must be maintained.   

 

This appliance must not share or be connected to a chimney flue serving any other appliance.   

 

Keep area around the appliance clear of combustible materials, gasoline and other flammable vapor and liquids.  

 

The flow of combustion and ventilation air must not be obstructed. 

  

 

Due  to  high  temperatures  the  appliance  should  be  located  out  of  traffic  and  away  from  furniture  and  draperies. 

 

The  glass  front  or  any  part  removed  for  servicing  the  appliance  must  be  replaced  prior  to  operating  the  appliance. 
Work should be done by a qualified service technician.   

 

Clean glass only when cool and only with non-abrasive cleansers.   

 

WARNING: DO NOT OPERATE APPLIANCE WITH THE GLASS/FRAME ASSEMBLY REMOVED, CRACKED 
OR  BROKEN.  REPLACEMENT  OF  THE  GLASS  SHOULD  ONLY  BE  PERFORMED  BY  A  LICENSED  OR  
QUALIFIED SERVICE PERSON . 

 

The glass assembly, Part #MTK-057T,  shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co., Inc. 
DO NOT SUBSTITUTE MATERIALS.   

 

Do not strike or slam glass assembly.   

 

Any  safety  screen  or  guard  removed  for  servicing  the  appliance  must  be  replaced  prior  to  operating  the  appliance. 

 

Under  no  circumstances  should  any  solid  fuel  (wood,  coal,  paper  or  cardboard  etc.)  be  used  in  this  appliance. 

 

Keep burner and control compartment clean. 

 

 

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect this 
appliance  and  to  replace  any  part  of  the  control  system  and  any  gas  control  which  has  been  under  water. 

This fireplace has been tested by OMNI-Test Laboratories, Portland, Oregon and complies with:  
 
ANSI  Z21.88-2009/CSA 2.33-2009, “Standard for Vented Gas Fireplace Heaters”    
CAN/CGA 2.17-M91 (R2009), “Gas-Fired Appliances for Use at High Altitudes” 

 

CAN/CSA P.4.1-09, “Testing Method for Measuring Annual Efficiency” 

 

 
This  installation  must  conform  with  local  codes,  or  in  the  absence  of  local  codes,  with  the 

National  Fuel  Gas  Code,  ANSI  Z223.1/NFPA  54,  

or the 

Natural Gas and Propane Installation Code, CSA B149.1 

  

 

The  appliance,  when  installed,  must  be  electrically  grounded  in  accordance  with  local  codes  or,  in  the  absence  of  local  codes,  wth  the

  National 

Electrical Code, ANSI/NFPA 70,  or the Canadian Electrical Code, CSA C22.1. 

  

 

   

Содержание 55345-IPI

Страница 1: ...his appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas i...

Страница 2: ......

Страница 3: ...but customer safety as well We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong Dudley Hussong President Boa...

Страница 4: ......

Страница 5: ...ENTS Mantel Requirements 11 GLASS FRAME ASSEMBLY Glass Frame Assembly Removal 11 Glass Frame Assembly Installation 11 GAS LINE CONNECTION Gas Line Connection 12 VENTING Approved Venting 13 Restrictor...

Страница 6: ...structed Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies The glass front or any part removed for servicing the appliance must be replaced...

Страница 7: ...appliance or equipment The sign shall read in print no less the one half inch 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side...

Страница 8: ...m 902mm 673mm 254mm TOP FRONT RIGHT LEFT 876mm 10 2 1 26 34 35 8 7 40 43 4 121mm 4 325 8 829mm 213 8 543mm 291 4 743mm 441 2 1130mm 21 4 57mm 101 4 260mm 1 2 1 2 1038mm 902mm 673mm 254mm TOP FRONT LEF...

Страница 9: ...r flat wall application 2 If masonry optional is used prepare foundation for the masonry load A lintel is required to support the added weight above fireplace 3 Attach nailing flanges to fireplace 4 I...

Страница 10: ...BRACKETS Figure 7b FRAMING STUD NAILING FLANGE FRAMING STUD 1 2 13mm CLEARANCE FRONT VIEW AS SHIPPED NAILING FLANGES INSTALLED NAILING FLANGE STAND OFF TAB TOP VIEW BACK VIEW STAND OFF TAB When insta...

Страница 11: ...ration requires a minimum 5 127mm exterior wall depth when using minimum horizontal venting Anything less than a 5 127mm exterior wall depth requires that you add that depth to the 21 7 8 556mm dimens...

Страница 12: ...ull door faces Determine exact position of your fireplace including hearth height width and depth if applicable If possible place fireplace in such a manner that vent termination will be placed betwee...

Страница 13: ...depth shown TYPICAL VERTICAL INSTALLATION TYPICAL CORNER INSTALLATION 1 1 IMPORTANT Kozy Heat wall thimble pass thru 800 WPT or 800WPT2 must be used on all horizontal vent runs Follow instructions on...

Страница 14: ...mbly bottom REMOVE GLASS FRAME ASSEMBLY 1 Locate spring loaded handles securing glass frame assembly at top bottom of firebox 2 Pull bottom handles out and down to release glass frame assembly bottom...

Страница 15: ...r and manual shut off valve The gas line should be run to the point of connection where the shut off valve and flexible gas line will connect The appliance and its individual shutoff valve must be dis...

Страница 16: ...ket Each installation is unique and affected by various factors including venting configuration altitude and climate Therefore after fireplace installation is complete a restrictor may be required or...

Страница 17: ...t heat shield must be installed when using a 45 degree elbow to horizontally position the vent system Exception corner installations Kozy Heat Wall Pass thru 800 WPT 4 1 2 114mm 6 1 2 165mm wall thick...

Страница 18: ...s Secure to exterior wall with screws not provided FRAMING DIMENSIONS FOR 800 WPT KOZY HEAT WALL PASS THRU CUT RING OUT OF BOTH SECTIONS IF INSTALLING 800 1 SERIES FLEX VENTING INSULATION HEAT SHIELD...

Страница 19: ...ft 9 14m total VENTING Termination Cap Min 2ft 610mm Max 30ft 9 14m 45 Elbow COMBUSTION AIR INTAKE SETTINGS VERTICAL TERMINATION HEIGHT SETTING GAS TYPE 0 10ft 0 3 05m 1 NAT 11 20ft 3 35m 6 10m 2 NAT...

Страница 20: ...e D Secure with 3 evenly spaced screws ILLUSTRATION ON FOLLOWING PAGE 4 Place a bead of sealant outside 5 flex pipe collar C end with EXTERNAL lip sliding it inside 5 pipe on top of fireplace D Secure...

Страница 21: ...A TERMINATION BOX B SLOTS IN EXTERIOR WALL PLATE C 5 FLEX PIPE COLLAR D 5 PIPE ON FIREPLACE OR EXTENSION KIT E 8 FLEX PIPE COLLAR F 8 PIPE ON FIREPLACE OR EXTENSION KIT G VINYL SIDING PROTECTOR H INT...

Страница 22: ...to any other appliance CANADA 12 305mm US 9 229mm K Mechanical air supply inlet CANADA 6ft 1 83m US 3ft 914mm above if within 10ft 3 05m horizontally Massachusetts installations 10ft 3 05m L Above pav...

Страница 23: ...er 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27 Over 20 12 to 21 12 8 0 2 44 VENT TERMINATION CLEARANCES Figure 20a CAUTION This appliance must not be connected to or joined with any chimney f...

Страница 24: ...place Klinkers in this area Do not place Klinkers directly on burner ports Use a steel or stiff bristle nylon brush to distribute Rock Wool Embers onto logs and burner NOTE Log numbers are located on...

Страница 25: ...ht log grate legs Remove from firebox by lifting front of burner assembly up out of flange while pushing pilot assembly back slightly 11 Remove screws securing front burner assembly Remove front burne...

Страница 26: ...l light kit halogen bulbs light cylinders and amber light filters if previously removed 9 Reinstall log set Page 21 10 Reconnect gas line to manual shut off valve 11 Reconnect any wall switch remote c...

Страница 27: ...er air passage keeping in mind this is a fairly tight fit 3 Partially thread 2 screws included in components packet into nuts at each end of lower grill Secure to fireplace by threading screws into co...

Страница 28: ...ESTRICTOR USAGE Turn fireplace on and allow to burn for 15 minutes If flames indicate there is excessive draft flickering short flames a restrictor may be necessary If flames indicate insufficient dra...

Страница 29: ...NSTALLATION WARNING Burner tube adjustable venturi positioning should only be performed by a qualified professional service technician Figure 26a Lazy yellow flames ideal Short blue flames venturi ope...

Страница 30: ...aise damper control up and push into mounting slot The damper is now in the fully open position and allows more heat to exit through the vent system If more heat is desired pull handle out and down Th...

Страница 31: ...disconnected from electrical current and cleaned vacuumed every six months The bearings are sealed and require no oiling IMPORTANT ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRI...

Страница 32: ......

Страница 33: ...in material or workmanship at Hussong Manufacturing Co Inc s expense including reasonable labor costs to repair or replace the defective component if a factory pre authorization is given for the repa...

Страница 34: ......

Страница 35: ...e time of this Lifetime Warranty or to accept on Hussong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit Hussong Manufacturing Co Inc may fully discharge a...

Страница 36: ...lation adjustment alteration service or maintenance can cause injury or property damage Refer to fireplace installation manual and this manual For assistance or additional information consult a qualif...

Страница 37: ...SCHEMATICS Wiring Schematics 4 OPERATING INSTRUCTIONS Control System Components 5 6 Lighting and Shutdown Instructions 10 12 Pressure Testing 13 System Operations 7 9 TROUBLESHOOTING Troubleshooting...

Страница 38: ...structed Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies The glass front or any part removed for servicing the appliance must be replaced...

Страница 39: ...TK 3 pc Grill Assembly IPI 028 IPI Fan Kit 700 308 Remote Control 55345 MV NATURAL GAS LP GAS MINIMUM INLET GAS PRESSURE 5 WC 1 25 kPa 7 WC 1 74 kPa recommended 11 WC 2 74 kPa recommended MAXIMUM INLE...

Страница 40: ...ELECTRICITY 120V AND OR BATTERIES TO OPERATE USING BATTERY BACK UP WILL OPERATE BURNER ONLY FAN AND LIGHT COMPONENTS WILL NOT FUNCTION ON BATTERY BACK UP POWER Figure 4a To Fan To Lights Pilot Assemb...

Страница 41: ...EM COMPONENTS Figure 5a REMOTE CONTROL Valve Terminals Gas Control Knob Step Motor Pilot Hood Thermopile Thermocouple PILOT ASSEMBLY Figure 5c Electrode GAS VALVE Manifold Pressure Tab Inlet Pressure...

Страница 42: ...Using the end of a paper clip or other similar object press button through hole marked PRG on receiver front cover Receiver will beep three 3 times to indicate it is ready to synchronize with a transm...

Страница 43: ...the Thermostat Key The LCD display will change to show the room thermostat is ON and set temperature is now displayed To adjust set temperature press Up or Down arrow keys until desired set temperatu...

Страница 44: ...The auxiliary function controls the AUX power outlet on the Fan control module which in turn controls the light kit 1 Use MODE key to guide you to AUX icon 2 Press Up Arrow Key to turn light kit on p...

Страница 45: ...umber of ignitions changes to room thermostat set point etc When transmitter batteries are low a Battery Icon will appear on the LCD display before all battery power is lost When batteries are replace...

Страница 46: ...OSS OF LIFE FOR YOUR SAFETY READ BEFORE LIGHTING A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around...

Страница 47: ...ghtly and turn counterclockwise to PILOT 7 Push valve knob in and hold while repeatedly pressing piezo igniter button until pilot is lit while continuing to hold in gas control knob 8 Hold gas control...

Страница 48: ...ol knob to OFF DO NOT FORCE TURN BURNER OFF TURN PILOT OFF NOTE The pilot will stay lit NOTE This control valve has an interlock device If pilot has been turned off it cannot be relit until thermocoup...

Страница 49: ...Press hand held remote ON button and note manometer reading 6 Press hand held remote OFF button 7 Disconnect manometer hose and tighten screw clockwise Screw should be snug do not over tighten 8 Atta...

Страница 50: ...pressure Consult with plumber or gas supplier No LP in tank Check LP propane tank Refill if necessary Wiring disconnection Use wiring schematic in this manual to determine that all wiring connections...

Страница 51: ...G Improper log placement Refer to corresponding pages in this installation manual Improper venturi setting Venturi may need to be opened slightly to allow more air into the gas mix Improper pitch on h...

Страница 52: ...way of injector turn counter clockwise to remove from injector journal 3 Place hex key into end of injector included with kit install into injector journal turning clockwise to a recommended torque of...

Страница 53: ...es Chart below states proper pressure readings Visually check pilot flame Flame should envelope top of flame sensor and extend onto burner far enough for proper ignition To Adjust Pilot Turn pilot adj...

Страница 54: ...setting slightly WARNING Burner tube adjustable venturi positioning should only be performed by a qualified professional service technician Figure 18a Lazy yellow flames ideal Short blue flames ventur...

Страница 55: ...current and cleaned vacuumed every six months The bearings are sealed and require no oiling IMPORTANT ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE...

Страница 56: ...MENT PARTS LIST COMBUSTIBLE MATERIAL BACKER BOARD MTK FPS FirePro Standoff 55345 MV CONTROL BOARD AND PARTS MTK 700 Control Board Nat Gas 700 203 Manual Shut off Valve MTK 701 Control Board LP Gas 700...

Страница 57: ...tallation adjustment alteration service or maintenance can cause injury or property damage Refer to fireplace installation manual and this manual For assistance or additional information consult a qua...

Страница 58: ...WIRING SCHEMATICS Wiring Schematics 4 OPERATING INSTRUCTIONS Control System Components 5 System Operations 6 9 Pressure Testing 12 Lighting and Shutdown 10 11 TROUBLESHOOTING Troubleshooting 13 14 CO...

Страница 59: ...structed Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies The glass front or any part removed for servicing the appliance must be replaced...

Страница 60: ...0 MTK 3 pc Grill Assembly IPI 028 IPI Fan Kit 700 408 Remote Control 55345 IPI NATURAL GAS LP GAS MINIMUM INLET GAS PRESSURE 5 WC 1 25 kPa 7 WC 1 74 kPa recommended 12 WC 2 99 kPa recommended MAXIMUM...

Страница 61: ...ATTERY BACK UP WILL OPERATE BURNER ONLY FAN AND LIGHT COMPONENTS WILL NOT FUNCTION ON BATTERY BACK UP POWER Figure 4a Flame Sensor SW1 Button red Igniter Pilot Pilot Burner 885 Proflame Battery Pack M...

Страница 62: ...essure tap Pilot flame adjustment Figure 5b Blue back lit LCD display ON OFF Key Thermostat Key UP DOWN Arrow Key Mode Key Transmission Thermostat OFF ON SMART Set Point Temperature Level State Flame...

Страница 63: ...and icon on the screen A single beep from IFC control module will confirm reception of the command Figure 6b Figure 6c MANUALLY CONTROL FLAME WITH REMOTE CONTROL The remote control has six 6 flame le...

Страница 64: ...play on LCD screen SMART THERMOSTAT Remote Control Operation Figure 7b Figure 7a KEY LOCK This function locks the keys to avoid unsupervised operation To Activate Press MODE and UP keys at same time T...

Страница 65: ...arious factors including battery quality number of ignitions changes to room thermostat set point etc When backup batteries are low a double beep will be emitted from the IFC control module when it re...

Страница 66: ...n third ignition attempt there will be a 60 second delay before the main burner lights If after this third attempt there is still no positive ignition the IFC control module will go into LOCK OUT and...

Страница 67: ...TION THIS IS NORMAL AND DOES NOT AFFECT THE PERFORMANCE OR LONGEVITY OF THE FIREPLACE 1 This appliance is equipped with an ignition device which automatically lights the pilot DO NOT try to light the...

Страница 68: ...power to the appliance 5 Press hand held remote ON button TO TURN GAS OFF TO APPLIANCE 1 Press hand held remote OFF button 2 Turn OFF all electric power to appliance if service is to be performed 3 Ma...

Страница 69: ...CAN CAUSE DELAYED IGNITION 1 Loosen inlet IN pressure tap screw counter clockwise 2 Attach manometer using a 5 16 I D hose 3 Set IPI CPI switch to CPI setting 4 Light pilot Note manometer reading 5 Mo...

Страница 70: ...pressure Consult with plumber or gas supplier No LP in tank Check LP propane tank Refill if necessary Wiring disconnection Use wiring schematic in this manual to determine that all wiring connections...

Страница 71: ...proper vent cap installation Blockage or vent system leaks NO REACTION TO COMMAND Backup battery pack batteries or remote control batteries low Replace batteries No communication between remote contr...

Страница 72: ...y of injector turn counter clockwise to remove from injector journal 3 Place hex key into end of injector included with kit install into injector journal turning clockwise to a recommended torque of 9...

Страница 73: ...s Chart below states proper pressure readings Visually check pilot flame Flame should envelope top of flame sensor and extend onto burner far enough for proper ignition To Adjust Pilot Turn pilot adju...

Страница 74: ...ENING CREATE DRAMATIC RESULTS ADJUST AT SLIGHT INCREMENTS UNTIL DESIRED LOOK IS ACHIEVED ALWAYS BURN FIREPLACE FOR AT LEAST 15 MINUTES AND ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS FLAM...

Страница 75: ...SAGEWAYS OF THE APPLIANCE BE KEPT CLEAN Annual examination of venting system by a qualified agency is required IF VENT AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON RE INSTALL PER INSTRUCTIONS PROV...

Страница 76: ...availability and pricing 55345 IPI REPLACEMENT PARTS LIST COMBUSTIBLE MATERIAL BACKER BOARD MTK FPS FirePro Standoff 55345 IPI CONTROL BOARD AND PARTS MTK 150 Control Board Nat Gas 700 504 1 Valve St...