23
1. Place control board in firebox, aligning holes in control board with
holes in firebox bottom. MAKE SURE SEALING GASKET IS
IN PLACE ON FIREBOX BOTTOM! Secure control board to
firebox bottom with (8) screws previously removed.
2. Reinstall optional light kit light kit stands if previously removed.
3. Place venturi spacers onto venturi mounting studs.
4. Re-install front burner assembly, making sure burner tube is
positioned over burner orifice. Secure with screws previously
removed.
5. Reinstall back burner/log grate assembly by positioning burner
tube into venturi collar on control board and pilot assembly
through rectangular opening. Secure front left and back right legs
with screws previously removed.
6. Reinstall pilot shield.
7. Reinstall ember refractory.
8. Reinstall optional light kit halogen bulbs, light cylinders and
amber light filters if previously removed.
9. Reinstall log set. Page
21.
10. Reconnect gas line to manual shut-off valve.
11. Reconnect
any
wall
switch,
remote
control
or
thermostat wires to top and bottom terminals on gas valve or
re-connect all wiring harnesses to gas valve. Plug all components
into electrical outlet.
12. Reinstall glass frame assembly. Page 11.
13. Reinstall upper louver & upper hood. Page 24.
14. Turn gas on.
15. Verify proper log placement, operation of fireplace, and any
electrical components.
RE-CONNECT REMOTE / THERMOSTAT WIRES
CONTROL BOARD INSTALLATION
NOTE
Your components may look slightly different than ones shown.
CAUTION
CHECK ALL CONNECTIONS FOR LEAKS WITH SOAPY WATER, WHETHER FIELD OR FACTORY MADE.
INSTALL (8) SCREWS
Figure 23a
INSTALL (2) SCREWS
INSTALL (2) SCREWS
CAUTION
If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before
removing any components.