21
#MTK-50A LOG SET INSTALLATION
#1
Position log #1 onto burner, setting backside of log against flange
at back. Pull log forward approximately 1/2” (13mm).
Position logs #2, #3 & #6 onto burner as shown above.
#3
#2
#6
#11
#4
Position log #4 as shown. Install #11 log over burner jumper tube.
Position logs #7 - #10 onto base logs, aligning holes in logs to
protrusions on base logs and log grate.
#10
#9
#8
#7
#12
Align notch in log #12 to log grate while positioning bottom
mounting hole to protrusion in log #8.
Randomly place ‘Klinkers’ in this area. Do not place ‘Klinkers’
directly on burner ports.
Use a steel or stiff bristle nylon brush to distribute Rock Wool
Embers onto logs and burner.
NOTE
Log numbers are located on bottom of each log. Refer to following instructions and illustrations for proper placement.
ATTENTION
If converting to LP (propane) gas or installing optional light kit do so now before installing log set. Follow instructions included
with kit. (Sold separately).
CAUTION
Do not place logs directly over burner port holes. Improper log placement may affect flame appearance and cause excessive
soot to build up on logs and glass.
Figure 21a
Figure 21b
Figure 21f
Figure 21d
Figure 21e
Figure 21c