6. Apply a bead of high temperature sealant to
the intake and exhaust collars located on the
back of the insert. Fully connect the intake
venting pipe to the intake collar, and the
exhaust venting pipe to the exhaust collar.
Extra caution is necessary to ensure the
proper venting is connected to the
appropriate venting collars.
Secure the flex
pipes in place with two 3” adjustable hose
clamps. Install sheet metal screws through the
flex pipes and collars to ensure permanent
connection.
9
7. Assemble the surround package (see
Surround Assembly section).
8. Place the surround in front of the fireplace
opening.
9. Slide the insert into the fireplace opening
completely until the insert rests firmly against
the surround.
WARNING:
The Gas Appliance And Venting System Must
Be Vented Directly To The Outside Of The
Building, In Accordance With All Regulatory
Requirements, And Never Be Attached To A
Chimney Serving A Separate Solid Fuel Or
Gas Burning Appliance.
Figure: 4 – Diagram showing proper and
improper installations.
Your First Fire
This section of the manual has been included as a last check for the installer, prior to leaving
the unit with the new owner. Please read all steps fully and ensure that they have been
satisfied.
1. Visually inspect the installation of the insert, and ensure that everything is in
accordance with the previous instructions.
2. Turn the gas supply ON, and check each connection for leakage. If any leaks
are detected, proper measures should be taken to repair.
3. Open the control compartment door, and locate the manifold test point on the gas
valve. Attach a pressure gauge to this line to test the outlet pressure from the
valve.
4. Referring to the operating instructions on how to light the insert, turn the burner
ON.
5. Turn the gas valve regulator to the HI position and check the manifold pressure
with the gauge. This pressure should be: 3.5” w.c. for Natural Gas, and 10” w.c.
for Liquid Propane. If the pressure exceeds these values, replacement /