the logs are being cleaned, use a very soft paintbrush, as the logs are fragile and 
can be easily damaged. 

 

Always clean the glass doors when the unit is cold.  Never clean when hot.  Wipe 
glass, grill, door and appliance with a non-linting soft damp cloth. Avoid the use of 
abrasive cleansers. The plated door and grill may scratch if abrasives are used. 

 

This appliance and venting system must be inspected prior to use; and at least 
annually thereafter by a qualified technician or service agent, to ensure that the flow 
of combustion and ventilation air remains unobstructed and the venting remains 
structurally sound.  Visually inspect the flue connection. This may require pulling the 
stove out from the fireplace opening.  If the venting needs to be removed for 
cleaning, make sure to reassemble and reseal the venting according to the steps 
discussed in the Venting Installation section earlier in this manual.  During the annual 
service calls the burner should be removed and cleaned. Take extra caution not to 
block the pilot assembly. 

 

The glass doorframe and the grill have been plated with 24-carat gold.  When 
cleaning is required, use only a soft damp cloth to wipe the surfaces when the unit is 
cold.  Never attempt to clean the unit when hot. 

 

Inspect the door gasket regularly, and if it requires replacing, use ¾” fibre glass 
braided rope. (APR # DV1-605) 

Log Replacement 

 

If replacement logs are required, you must use only the proper log sets which have been 
tested and certified for use with the 

KOZI

 DV1-MI Direct Vent Gas Insert

.  For details 

on how to obtain replacement logs, contact the manufacturer or your local 

KOZI

 dealer. 

 

Glass Replacement 

 

This 

KOZI

 DV1-MI Direct Vent Gas Insert

 has been tested and certified with high-

temperature ceramic glass panels for your protection.  This ceramic glass has been 
engineered to withstand the highest temperatures your appliance will produce.  If 
however, this glass is shattered or cracked due to impact or collision, do not use the 
insert.  The complete window and frame assembly must be replaced with a new or 
rebuilt assembly as supplied by the manufacturer or dealer.  Only doors certified with the 
appliance by the manufacturer can be used.  Broken or damaged glazing should be 
removed with care (using gloves) to avoid injury. 
 
Replacement parts should only be obtained directly from authorized 

KOZI

 dealers or the 

manufacturer.  Substitutes are 

NOT

 permitted.  Substituting materials for repair or 

replacement other then as suggested or supplied by the dealer or manufacturer could 
cause a safety hazard.   
 
The ceramic glass window is very strong but should not be abused by striking it, 
slamming it or any inappropriate actions. 
 
 

 

 

15 

Содержание DV1-M1

Страница 1: ...d liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS o Do not try to light any appliance o Do not touch electrical switches do not use the phone in your building o Imme...

Страница 2: ...fety Certification Information 6 Installation 7 Firebox Preparation 7 Venting Installation 7 Insert Installation 8 Your First Fire 9 Log Installation 10 Surround Assembly 11 Operating Instructions 12...

Страница 3: ...g a separate solid fuel burning appliance Never vent into another room or inside a building 6 This insert is Direct Vented The fresh combustion air required by this gas stove is drawn from outside the...

Страница 4: ...ocated on the front of the valve body The appliance and it s appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure...

Страница 5: ...im the excess later Fireplace Requirements and Clearances to Combustibles Description Width Height Depth Minimum Fireplace Opening 22 20 5 16 Maximum Opening With Surround 1 39 29 Maximum Opening With...

Страница 6: ...panel that can be pulled out from the control compartment Note Due to constant development KOZI units and technologies are consistently being upgraded Please ensure that the label contained on this pa...

Страница 7: ...ation The extra cleaning required before you install the insert into the firebox is essential because of the circulation fan mounted inside the unit This fan will pick up the odor from the creosote as...

Страница 8: ...e chimney opening until the bottom plate of the adapter box rests on top of the chimney cover plate Fasten the adapter box to the chimney Figure 2 Assembly diagram of venting components Insert Install...

Страница 9: ...Never Be Attached To A Chimney Serving A Separate Solid Fuel Or Gas Burning Appliance Figure 4 Diagram showing proper and improper installations Your First Fire This section of the manual has been inc...

Страница 10: ...arge odors You may have to repeat this process several times Log Installation 1 Turn the burner switch to OFF Turn the gas valve OFF Allow the unit time to cool 2 Remove the side panels of the stove b...

Страница 11: ...of the correctly positioned logset Surround Assembly 1 Assemble the surround as shown in the diagram provided below Make sure to fasten the nut to the bolt securely 1 Attach the brass trim to the surr...

Страница 12: ...r Near The Appliance Any And All Equipment Removed From This Unit For Maintenance Or Servicing Must Be Reinstalled Prior To Further Operation Of This Unit Under No Circumstances Should This Unit Be Mo...

Страница 13: ...t or flame height 8 Close the control compartment door while operating the unit Shutdown Instructions 1 Open the control compartment door 2 Turn the burner switch to the OFF position This will turn of...

Страница 14: ...The Manufacturer Of Your Local KOZI Dealer The Use Of Substitute Parts Can Alter The Performance Characteristics Of This Unit And Could Cause Serious Health And Safety Conditions To Arise CAUTION Any...

Страница 15: ...lean the unit when hot Inspect the door gasket regularly and if it requires replacing use fibre glass braided rope APR DV1 605 Log Replacement If replacement logs are required you must use only the pr...

Страница 16: ...counted for continue with the following instructions 1 Turn the main burner switch OFF turn the gas control knob to the OFF position and allow time for the unit to cool Turn OFF or disconnect the gas...

Страница 17: ...hten the screws securely Tighten the new orifice completely Figure 7 Schematic illustration of the Pilot Assembly and components 8 Adjust the primary air setting on the burner assembly by loosening an...

Страница 18: ...lt Diagrams Shown below are the wiring schematics for the blower and gas valve assemblies CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and da...

Страница 19: ...03 Trim Moulding Side DV1 MI 104 Trim Moulding Top DV1 105 KOZI Logo 2 DV1 2 Burner Body Assembly 3 DV1 3 Control Door Assembly DV1 301 Door Handle 4 DV1 4 Hearth 5 DV1 5 Door Support 6 DV1 6 Glass Do...

Страница 20: ...xplosion Gate Assembly DV1 2003 Explosion Gate Gasket 21 DV1 21 Explosion Gate Bracket 22 DV1 22 Mounting Plate Assembly DV1 2202 Gas Valve Mounting Bracket DV1 2203 Gas Orifice Mounting Bracket DV1 2...

Страница 21: ...d in accordance with the applicable rating plate Discoloration and expansion movement of certain parts is normal and will not be covered under warranty Gas Valve and Electrical Components Gas and elec...

Отзывы: