background image

 
 
 

 

Owner’s Manual 

Direct Vent Gas Masonry Insert 

*Installation * Operation * Service * Parts * 

Model Number: DV1-M1 

 
 
 
 
 
 
 
 
Appliance Type:  Direct Vent Gas Stove Heater for installation in solid fuel fireplace. 
Test Standard:  Harmonized, ANSI Z21.88 CSA 2.33/2002, CAN/CGA 2.17 
 
Proper installation, operation and maintenance procedures are critical to all gas fired 
appliances.  Please read this manual thoroughly and retain for future use.  
 
WARNING:  If the information in these instructions is not followed exactly, a fire or 
explosion may result causing property damage, personal injury or loss of life 
 

  Do not store or use gasoline or other flammable vapours and liquids in the 

vicinity of this or any other appliance. 

 

  WHAT TO DO IF YOU SMELL GAS 

 

o

  Do not try to light any appliance 

o

  Do not touch electrical switches’ do not use the phone in your building. 

o

  Immediately call your gas supplier from a neighbour’s phone. 

o

  Follow your gas supplier’s instructions. 

o

  If you cannot reach your gas supplier, call the fire department. 

 

  Installation and service must be performed by a qualified installer, service agency 

or gas supplier.   

 
This appliance may be installed in an aftermarket permanently located, manufactured 
(mobile) home, where not prohibited by local codes. 
 
This appliance is only for use with other gases, unless a certified kit is used.

 

 
 

APR Industries Ltd.  1354 Waverley Street, Winnipeg, Manitoba, Canada, R3T 0P5 

Tel.  (204 452-9907     Fax (204) 453-2747     Email:  [email protected]

 

TESTED BY: 

Rev. June 2006

Содержание DV1-M1

Страница 1: ...d liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS o Do not try to light any appliance o Do not touch electrical switches do not use the phone in your building o Imme...

Страница 2: ...fety Certification Information 6 Installation 7 Firebox Preparation 7 Venting Installation 7 Insert Installation 8 Your First Fire 9 Log Installation 10 Surround Assembly 11 Operating Instructions 12...

Страница 3: ...g a separate solid fuel burning appliance Never vent into another room or inside a building 6 This insert is Direct Vented The fresh combustion air required by this gas stove is drawn from outside the...

Страница 4: ...ocated on the front of the valve body The appliance and it s appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure...

Страница 5: ...im the excess later Fireplace Requirements and Clearances to Combustibles Description Width Height Depth Minimum Fireplace Opening 22 20 5 16 Maximum Opening With Surround 1 39 29 Maximum Opening With...

Страница 6: ...panel that can be pulled out from the control compartment Note Due to constant development KOZI units and technologies are consistently being upgraded Please ensure that the label contained on this pa...

Страница 7: ...ation The extra cleaning required before you install the insert into the firebox is essential because of the circulation fan mounted inside the unit This fan will pick up the odor from the creosote as...

Страница 8: ...e chimney opening until the bottom plate of the adapter box rests on top of the chimney cover plate Fasten the adapter box to the chimney Figure 2 Assembly diagram of venting components Insert Install...

Страница 9: ...Never Be Attached To A Chimney Serving A Separate Solid Fuel Or Gas Burning Appliance Figure 4 Diagram showing proper and improper installations Your First Fire This section of the manual has been inc...

Страница 10: ...arge odors You may have to repeat this process several times Log Installation 1 Turn the burner switch to OFF Turn the gas valve OFF Allow the unit time to cool 2 Remove the side panels of the stove b...

Страница 11: ...of the correctly positioned logset Surround Assembly 1 Assemble the surround as shown in the diagram provided below Make sure to fasten the nut to the bolt securely 1 Attach the brass trim to the surr...

Страница 12: ...r Near The Appliance Any And All Equipment Removed From This Unit For Maintenance Or Servicing Must Be Reinstalled Prior To Further Operation Of This Unit Under No Circumstances Should This Unit Be Mo...

Страница 13: ...t or flame height 8 Close the control compartment door while operating the unit Shutdown Instructions 1 Open the control compartment door 2 Turn the burner switch to the OFF position This will turn of...

Страница 14: ...The Manufacturer Of Your Local KOZI Dealer The Use Of Substitute Parts Can Alter The Performance Characteristics Of This Unit And Could Cause Serious Health And Safety Conditions To Arise CAUTION Any...

Страница 15: ...lean the unit when hot Inspect the door gasket regularly and if it requires replacing use fibre glass braided rope APR DV1 605 Log Replacement If replacement logs are required you must use only the pr...

Страница 16: ...counted for continue with the following instructions 1 Turn the main burner switch OFF turn the gas control knob to the OFF position and allow time for the unit to cool Turn OFF or disconnect the gas...

Страница 17: ...hten the screws securely Tighten the new orifice completely Figure 7 Schematic illustration of the Pilot Assembly and components 8 Adjust the primary air setting on the burner assembly by loosening an...

Страница 18: ...lt Diagrams Shown below are the wiring schematics for the blower and gas valve assemblies CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and da...

Страница 19: ...03 Trim Moulding Side DV1 MI 104 Trim Moulding Top DV1 105 KOZI Logo 2 DV1 2 Burner Body Assembly 3 DV1 3 Control Door Assembly DV1 301 Door Handle 4 DV1 4 Hearth 5 DV1 5 Door Support 6 DV1 6 Glass Do...

Страница 20: ...xplosion Gate Assembly DV1 2003 Explosion Gate Gasket 21 DV1 21 Explosion Gate Bracket 22 DV1 22 Mounting Plate Assembly DV1 2202 Gas Valve Mounting Bracket DV1 2203 Gas Orifice Mounting Bracket DV1 2...

Страница 21: ...d in accordance with the applicable rating plate Discoloration and expansion movement of certain parts is normal and will not be covered under warranty Gas Valve and Electrical Components Gas and elec...

Отзывы: