6.3.5 LOADER DEFECTS AND DAMAGE, INCORRECT USE OF SAFETY DEVICES
Damage and other faults of the loader or its attachment must be immediately reported to the operator so that the fault can
be rectified by the same.
Loaders and attachments that are not safe or functional must not be used until properly repaired.
Do not remove, disable or turn off safety devices or switches!
Predefined settings may only be changed with the manufacturer’s consent.
Works on the electronic system (such as connecting radio, additional headlights etc.) are only permitted with the manufac-
turer’s written consent. All interventions in the electrical system must be properly documented!
6.3.6 RISK TO STABILITY
To ensure stability, the following rules must be observed:
Only use tyres with the same and permitted level of wear on the same axle.
Use only wheels and tyres of the same type on the same axle, for instance superelastic tyres only.
Only use wheels and tyres approved by the manufacturer.
Use only high quality products.
Wheels and tyres approved by the manufacturer can be found in the spare parts list. If you want to use other wheels
or tyres, you must first obtain the manufacturer’s consent!
When changing wheels or tyres, always make sure that the loader never tilts to one side as a result (that is, always replace
all wheels at the same time). Modifications can only be made subject to consultation with the manufacturer. When changing
the type of tyres used on a single axle, for example from superelastic to pneumatic tyres, the load diagram must also be
changed accordingly.
More detailed information on these topics can be obtained from an authorized service center.
6.3.7 MEDICAL DEVICES
Only use devices that are sufficiently protected against electromagnetic interference. Medical devices such as pacemakers
or hearing aids may not function properly during the loader operation.
Check with your doctor or medical device manufacturer to make sure that it is sufficiently protected against electromagnetic
interference.
Warning
The loader may overturn; there is a risk of accident.
A failure to follow these instructions and information may result in compromised stability.
Warning
Electromagnetic interference with medical devices may occur.
!
!
6.4 INSULATION TEST
The insulation of the loader must provide sufficient insulation resistance. Consequently as part of the tests under the FEM
standard, the insulation resistance must be checked at least once a year in accordance with ČSN EN 1175, DIN 43539, VDE
0117 and VDE 0510. The results of the insulation tests must meet at least the test values given in the following two tables.
Contact an authorized service center if you want to carry out insulation tests!
6.5 SAFETY INSTRUCTIONS FOR HANDLING CONSUMABLES
6.5.1 ALLOWABLE CONSUMABLES
Non-compliance with the safety regulations applicable to consumables may result in injury, death or damage to the envi-
ronment!
Observe the safety regulations when handling such materials.
Allowable materials necessary for operation are listed in the maintenance data table.
6.5.2 OILS
Test values for the traction battery and the complete loader:
Warning
The electrical system of the loader and the traction battery must be checked separately!
Warning
Make sure that oils do not come into contact with hot machine parts! Oils are flammable.
COMPONENT
RECOMMENDED TEST
VOLTAGE
MEASUREMENT
RATED VOLTAGE U
BAT
TEST VALUES
Battery
50 V DC
Batt. + Batt. -
Battery
compart-
ment
24 V
> 1 200
100 V DC
48 V
> 2 400
100 V DC
80 V
> 4 000
RATED VOLTAGE
TEST VOLTAGE
TEST
VALUES
FOR NEW
LOADERS
MINIMUM VALUES OVER SERVICE LIFE
24 V
50 V DC
At least 50 k
> 24k
48 V
100 V DC
At least 100 k
> 48k
80 V
100 V DC
At least 200 k
> 80k