background image

system dst

Shows

current

daylight

saving

time

setting

in

format:

enabled/disabled

rrrr/mm/dd,hh:mm:ss

system dst

<

enable/disble

>

Enables/disables daylight saving time

system dst begin yyyy/mm/dd,hh:mm:ss

Sets daylight saving time beginning

system dst end yyyy/mm/dd,hh:mm:ss

Sets daylight saving time end

system sntp

Shows current SNTP client settings.

system sntp

<

enable/disable

><

sntp ip/domain

>

hows current SNTP client settings. Enables (

en-

able

), or disables (

disable

) time synchronization with SNTP server. Server address can be entered

both as IP address or domain name.

system time

<

YYYY/MM/DD,HH:MM:SS

>

Sets local time.

system time

Shows current local time.

system timezone

<

+/-offset

>

Sets local time zone. Time zone offset is presented in seconds.

system timezone

Shows current local time zone offset from UTC. Presented value is in seconds.

system update

Switches the system to

firmware upgrade

mode.

system reset to default

Resets all device settings to factory default values. After sending this com-

mand, factory default values are restored and the system restarts.

system webport

<

port

>

system kashport

<

port

>

5.3.4

CGI commands

NETIO-230B can easily be integrated into your applications using CGI commands.

CGI command device control uses the following command format:

http://

<

IPaddress

>

/tgi/control.tgi?

<

command

>

Replace the IP address of your device with the string

<

IP address

>

. The

<

command

>

string is the

actual command.

List of CGI commands:
h

ash=

h

ash Hash string request, hash is needed to generate encrypted password. Command returns

<

html

>

hash

<

/html

>

.

l

ogin=

<

p

/

c

>

:

<

user name

>

:

<

password

>

Login to the device. By typing

login=

p

lain

you choose

to login with unencrypted password. For encrypted login, select the command

login=

c

rypted

. Further

command parameters are login name and password. Command return values are:

<

html

>

555 FORBIDDEN

<

/html

>

You are not logged in or bad command.

<

html

>

100 HELLO

<

/html

>

- Successful login.

19

Содержание NETIO-230B

Страница 1: ......

Страница 2: ...nufacturer is not responsible for possible damage caused by improper usage or usage in unsuitable environment Device has been designed for indoor use only Do not use the device during the strong vibra...

Страница 3: ...ion 8 5 2 System configuration 10 5 2 1 Configuration of network parameters 11 5 2 2 E mail configuration 11 5 2 3 Date and time settings 12 5 2 4 Manage users 13 5 2 5 Firmware update 14 5 3 Serial P...

Страница 4: ...rs electric entrance gates security surveillance systems or any other 230V appliance directly or using the timer 1 1 Features Built in web server Supports wide range of Internet browsers Internet Expl...

Страница 5: ...d Internet browser Microsoft Internet Explorer Opera Mozilla Firefox 2 Interface Description 2 1 Side View Figure 1 side view 1 Fuse housing for main fuse 2 Device ON OFF switch 3 RJ 45 connector netw...

Страница 6: ...using the Ethernet cable with RJ 45 connectors Use cross cable when the device is directly connected to the PC 2 Connect the power cable to power outlet 3 Connect devices that you want to control to...

Страница 7: ...s are made to the device settings Utility will update the settings of your NETIO and show device list with changed parameters If there is DHCP server in your network and you are not willing to change...

Страница 8: ...trol the Menu on the left side Output Manual control page will show up figure 6 NETIO 230B can control all four outputs at the same time Choose which ports should be turned ON OFF and click Apply If y...

Страница 9: ...d parameters of this specific port Signifi cance of the individual parameters is described in the following text Output configuration No Port number 0 3 Name Port Output name PON state Default output...

Страница 10: ...Figure 7 set up ports Figure 8 output configuration 9...

Страница 11: ...it is possible to setup maximum allowed number of output restarts default value 3 Enable Turning on the Watchdog feature IP address IP address of the network device that will be monitored Timeout Max...

Страница 12: ...web interface Device name allows you to insert the name of your device for easier identification in the future Firmware version is just informative and shows the current firmware version After you mak...

Страница 13: ...nd the system date and time settings will appear on the right NETIO 230B supports two methods of getting the right date and time values It can be entered manually or obtained automatically from the SN...

Страница 14: ...me mManual local time set up with SNTP server synchronization off Daylight saving time and local time offset works both for automatic and SNTP set up If you do not specify Local Time Offset when the t...

Страница 15: ...y three seconds the Continue button is activated Click on it Now insert the firmware file xnetio bin and click Update Approximately two minutes procedure of firmware upload will follow After the firmw...

Страница 16: ...it number transmitted as 32 digit hexadecimal number 5 3 2 Communication via KSHELL interface To connect to your NETIO 230B please follow these steps 1 Open command prompt 2 Enter the command telnet 1...

Страница 17: ...in name crypted password User login with encrypted password version Shows firmware version alias Shows device name quit Logout If system changes have been made device restart is done reboot Logs out c...

Страница 18: ...mode once daily weekly Selection of timer option on time Output ON time off time Output OFF time week sched Number consisting of seven digits 0 or 1 first digit stands for Monday and the last one for...

Страница 19: ...vice will fail to respond to Ping commands after the third restart the output will stay OFF You will be notified by warning e mail after each reset of the output system eth Shows current network inter...

Страница 20: ...te Switches the system to firmware upgrade mode system reset to default Resets all device settings to factory default values After sending this com mand factory default values are restored and the sys...

Страница 21: ...The buttons correspond to outlets 1 4 from left to right 5 5 LED status indicators The LED indicators on the device are used to inform the user not only about the output status but also communicate ce...

Страница 22: ...To replace the fuse unscrew the fuse holder ideally using a flat screwdriver Always use an identical replacement fuse 250V 10A type F After insertion of the correct fuse replace the plastic holder and...

Отзывы: