background image

<

wd ip addr

>

- IP address of monitored device in seconds

<

wd timeout

>

- maximum response time of monitored device

<

wd POn delay

>

- Time (in seconds) for which the Watchdog feature will be inactive after

output restart. During this interval, the monitored device should recover to its normal opera-
tion after being restarted.

<

ping interval

>

- Interval (in seconds) in which the Ping requests to the monitored device will

be sent.

<

max retry

>

- Maximum allowed number of output restarts for the case that monitored device

does not respond to a

Ping

command. After the maximum number of retries is reached the

output will stay OFF.

<

max retry poff: enable/disable

>

- enable/disable the function

max retry

<

send email: enable/disable

>

- enable/disable sending of e-mail messages unavailability of

monitored device, eventually, upon overrun of the

max retry

value

Example:

The command

port wd 2 enable 192.168.10.101 10 30 1 3 enable enable

nable

enable will enable the

Watchdog

feature on output 2. Device on address 192.168.10.101 will be

monitored. Max Ping response time of monitored device will be 10 seconds. Ping commands will
be sent in 1 second intervals. If the monitored device won’t respond in 10 seconds, output 2 will
be turned OFF for 30 seconds. If the device will fail to respond to Ping commands after the third
restart the output will stay OFF. You will be notified by warning e-mail after each reset of the output.

system eth

Shows current network interface setup in format:

<

dhcp/manual

><

ip address

><

mask

><

gateway

>

system eth

<

dhcp/manual

>

[

<

ip address

><

mask

><

gateway

>

]

Setup of the network interface pa-

rameters – IP address, subnet mask and gate way parameters are needed to pass only if

manual

mode is entered. To allow changed values to take effect you must restart the device by typing the

reboot

command or turning it off and on again.

Example:

The command

system eth manual 192.168.10.150 255.255.255.0 192.168.10.1

will

set IP address 192.168.10.150, subnet mask 255.255.255.0 and default gateway 192.168.10.1.

email server

<

ip/domain server address

>

Sets IP address or domain name of the SMTP server.

system discover

<

enable/disable

>

Enables / Disable visibility of the device for the network

Discover

utility

.

system discover

hows if the option system

discover

is activated or deactivated.

system swdelay

<

delay

>

Sets delay between triggering two outputs. Value expressed in tenths of

seconds.

system swdelay

Shows current delay between triggering two outputs.

system dns

<

ip

>

Sets IP address of the DNS server. To allow changed values to take effect, you must

restart the device by typing the

reboot

command or switching NETIO off and on again.

system dns

Shows current IP address of the DNS server.

18

Содержание NETIO-230B

Страница 1: ......

Страница 2: ...nufacturer is not responsible for possible damage caused by improper usage or usage in unsuitable environment Device has been designed for indoor use only Do not use the device during the strong vibra...

Страница 3: ...ion 8 5 2 System configuration 10 5 2 1 Configuration of network parameters 11 5 2 2 E mail configuration 11 5 2 3 Date and time settings 12 5 2 4 Manage users 13 5 2 5 Firmware update 14 5 3 Serial P...

Страница 4: ...rs electric entrance gates security surveillance systems or any other 230V appliance directly or using the timer 1 1 Features Built in web server Supports wide range of Internet browsers Internet Expl...

Страница 5: ...d Internet browser Microsoft Internet Explorer Opera Mozilla Firefox 2 Interface Description 2 1 Side View Figure 1 side view 1 Fuse housing for main fuse 2 Device ON OFF switch 3 RJ 45 connector netw...

Страница 6: ...using the Ethernet cable with RJ 45 connectors Use cross cable when the device is directly connected to the PC 2 Connect the power cable to power outlet 3 Connect devices that you want to control to...

Страница 7: ...s are made to the device settings Utility will update the settings of your NETIO and show device list with changed parameters If there is DHCP server in your network and you are not willing to change...

Страница 8: ...trol the Menu on the left side Output Manual control page will show up figure 6 NETIO 230B can control all four outputs at the same time Choose which ports should be turned ON OFF and click Apply If y...

Страница 9: ...d parameters of this specific port Signifi cance of the individual parameters is described in the following text Output configuration No Port number 0 3 Name Port Output name PON state Default output...

Страница 10: ...Figure 7 set up ports Figure 8 output configuration 9...

Страница 11: ...it is possible to setup maximum allowed number of output restarts default value 3 Enable Turning on the Watchdog feature IP address IP address of the network device that will be monitored Timeout Max...

Страница 12: ...web interface Device name allows you to insert the name of your device for easier identification in the future Firmware version is just informative and shows the current firmware version After you mak...

Страница 13: ...nd the system date and time settings will appear on the right NETIO 230B supports two methods of getting the right date and time values It can be entered manually or obtained automatically from the SN...

Страница 14: ...me mManual local time set up with SNTP server synchronization off Daylight saving time and local time offset works both for automatic and SNTP set up If you do not specify Local Time Offset when the t...

Страница 15: ...y three seconds the Continue button is activated Click on it Now insert the firmware file xnetio bin and click Update Approximately two minutes procedure of firmware upload will follow After the firmw...

Страница 16: ...it number transmitted as 32 digit hexadecimal number 5 3 2 Communication via KSHELL interface To connect to your NETIO 230B please follow these steps 1 Open command prompt 2 Enter the command telnet 1...

Страница 17: ...in name crypted password User login with encrypted password version Shows firmware version alias Shows device name quit Logout If system changes have been made device restart is done reboot Logs out c...

Страница 18: ...mode once daily weekly Selection of timer option on time Output ON time off time Output OFF time week sched Number consisting of seven digits 0 or 1 first digit stands for Monday and the last one for...

Страница 19: ...vice will fail to respond to Ping commands after the third restart the output will stay OFF You will be notified by warning e mail after each reset of the output system eth Shows current network inter...

Страница 20: ...te Switches the system to firmware upgrade mode system reset to default Resets all device settings to factory default values After sending this com mand factory default values are restored and the sys...

Страница 21: ...The buttons correspond to outlets 1 4 from left to right 5 5 LED status indicators The LED indicators on the device are used to inform the user not only about the output status but also communicate ce...

Страница 22: ...To replace the fuse unscrew the fuse holder ideally using a flat screwdriver Always use an identical replacement fuse 250V 10A type F After insertion of the correct fuse replace the plastic holder and...

Отзывы: