Kortho
Hot Quickcoder User manual
16
6.2
Adjustment of the HQC
Figure 12: Adjustment of the HQC
A correct adjustment of the HQC is achieved by the setting of the stamping pressure, temperature
and stamping time.
The
stamping pressure
is adjusted with the reducing valve. This is mounted on the left-hand side of
the Control box (1). The
temperature
is set with the TEMP dial (2). The
stamping time
is set with the
PULSE/TIME dial (3).
Furthermore, the PRINT/DELAY dial (4) can be used to set a delay between the sensor signal and the
actual coding job through the Control box to the HQC.
STEPS:
1.
Set the stamping pressure to ± 4 bar.
2.
Set the temperature to position 8 (± 135°C).
3.
Set the stamping time such that an optimum print is generated. If necessary, the print quality
can be improved by slightly increasing the pressure and/or temperature.
If the print does not result in a completely even image, the position of the HQC probably needs to be
adjusted (see section 5.3).
!
WARNING:
Too high a temperature setting can reduce the service life of the Hotroll.
Too high an air pressure setting can reduce the service life of the Hot Quickcoder.
The standard optimum setting in most cases is an air pressure of ± 4 bar and a temperature of ± 135°C
(position 8). Adjust the setting so that both the temperature and the air pressure are around the standard
setting.
1 Reducing valve
2 Temperature setting
3 Pulse/Time setting
4 Print/Delay setting
Содержание H210 AM
Страница 1: ...kortho Hot Quickcoder Artikelnummer Articlenumber H210 AM NE...
Страница 5: ...Kortho Hot Quickcoder User Manual 5 ENGLISH MANUAL ENGELSE HANDLEIDING...
Страница 31: ...Kortho Hot Quickcoder User Manual 31 MULTI LANGUAGE SECTION...
Страница 33: ...Kortho Hot Quickcoder User Manual 33 Artikelnummer Item number 810387 Commandokast Control box HQC AT...
Страница 34: ...Kortho Hot Quickcoder User Manual 34 Artikelnummer Item number 809477 Standaard Steun Standard support HQC...
Страница 36: ...Kortho Hot Quickcoder User Manual 36 Artikelnummer Item number 810387 Commandokast Control box HQC AT...
Страница 39: ...Kortho Hot Quickcoder User Manual 39...