PUTTING THE HOT QUICKCODER INTO OPERATION
The correct operation of the HQC is determined by the setting of the stamping time, stamping
pressure and temperature and the distance of the HQC from the surface to be printed.
The description below assumes that:
•
The HQC has been installed so that it is easily accessible (see section 4).
•
The supply of products is interrupted.
•
The HQC is switched on.
5.1
Setting up the Control box
Figure 8: Setting up the Control box
The HQC can be switched On and Off with the ON (2) and OFF (1) buttons. The dials (9), (10) and
(11) are used respectively to adjust the temperature of the text head, the stamping duration and the
printing position on the product.
Switch on the system by pressing the ON button (2). The operating temperature of the HQC is
around 135° C in most instances. This means that a heating up time of 15 minutes (position 8) after
switching on the HQC should be taken into account. The system automatically switches to the
warming-up position after the ON button has been pressed. The red light next to the TEMP turn knob
(9) will be lit continuously.
No prints are made during the warming-up phase if a print signal is received. The HQC remains in the
STOP position during the warming-up phase and the orange light on the STOP button (5) is lit.
The warming-up phase is completed when the red light on the TEMP turn knob (9) blinks at a steady
rate.
After the warming-up phase, a testprint can be made by pressing the TEST button (3). To make a
testprint, however, the system needs to first be released by pressing the START button (4).
Depending on the quality of the testprint, the HQC may need to be adjusted. Otherwise, simply press
the START button (4) to prepare the HQC for production.
An explanatory overview of the buttons and turn knobs on the control box control panel is given in
Chapter 2.
1
OFF button
2
ON button
3
TEST button
4
START button
5
STOP button
6
Function button F1, F2
7
Text head IN
8
Text head OUT
9
Temperature adjustment
10 Pulse/time adjustment
11 Print delay adjustment
12 Reducing valve
13 HQC air connection
14 Mains connection
15 HQC connection
16 Coupling nut
Содержание H210 AM
Страница 1: ...kortho Hot Quickcoder Artikelnummer Articlenumber H210 AM NE...
Страница 5: ...Kortho Hot Quickcoder User Manual 5 ENGLISH MANUAL ENGELSE HANDLEIDING...
Страница 31: ...Kortho Hot Quickcoder User Manual 31 MULTI LANGUAGE SECTION...
Страница 33: ...Kortho Hot Quickcoder User Manual 33 Artikelnummer Item number 810387 Commandokast Control box HQC AT...
Страница 34: ...Kortho Hot Quickcoder User Manual 34 Artikelnummer Item number 809477 Standaard Steun Standard support HQC...
Страница 36: ...Kortho Hot Quickcoder User Manual 36 Artikelnummer Item number 810387 Commandokast Control box HQC AT...
Страница 39: ...Kortho Hot Quickcoder User Manual 39...