JetNet 4706/4706f Industrial Managed PoE Switch
74
4.10.2 CLI Commands for Security
Command Lines for Security configuration
Feature
Command Line
IP Security
IP Security
Switch(config)# ip security
Set ip security enable ok.
Switch(config)# ip security host 192.168.10.33
Add ip security host 192.168.10.33 ok.
Display
Switch# show ip security
ip security is enabled
ip security host:
192.168.10.33
4.11 Warning
JetNet 4706/4706f
provides several types of warning features for remote monitoring and
even provides a real-time alert mechanism. These features include a System Log for local
and remote servers, SMTP E-mail alerts and a Fault Relay alarm.
The following commands are included in this section:
4.11.1 Fault Relay Setting
4.11.2 Event Selection
4.11.3 Syslog Configuration
4.11.4 SMTP Configuration
4.11.5 CLI Commands for Warning
4.11.1 Fault
Relay
Setting
JetNet 4706/4706f
provides 1 digital output, also known as Relay Output. The relay
contacts are energized (open) for normal operation and will close under faulty conditions.
Faulty conditions include Power Failure, Ethernet port Link Failure, Ping Failure and Super
Ring Topology Change. You can enable and select relay trigger by clicking the
Apply
button.
Relay 1:
Check the box
Relay 1
, then select the Event Type and its parameters.