JetNet 4706/4706f Industrial Managed PoE Switch
10
3 Preparation for Management
The
Korenix JetNet 4706/4706f
Industrial Managed PoE Switch provides both in-band
and out-band configurations.
With out-band management; you can configure the switch via RS232 console cable if
you do not want to include your admin PC as part of your network. Also, in case you lose
network connection, you will still be able to configure the switch via RS232 console
cable. Out-band management is not affected by network performance.
In-band management allows you to remotely manage the switch via the network. You
can choose Telnet or Web-based management. You just need to know the device’s IP
address and you can remotely connect to its embedded HTTP web pages or Telnet
console.
The following topics are covered in this chapter:
3.1 Preparation for Serial Console
3.2 Preparation for Web Interface
3.3 Preparation for Telnet console
3.1 Preparation for Serial Console
In the
JetNet 4706/4706f
package,
Korenix
has included one RS-232 DB-9 to RJ-45
console cable. Attach the RS-232 DB-9 connector to your PC COM port, then connect
the RJ-45 to the console port of
JetNet 4706/4706f
. If you lose the cable, please follow
the console cable Pin assignment to find one (See
Appendix
).
1. Go to Start -> Program -> Accessories -> Communication -> Hyper Terminal
2. Give a name to the new console connection.
3. Choose the COM name
4. Select correct serial settings. The serial settings for the
JetNet 4706/4706f
are:
Baud Rate: 9600 / Parity Check: None / Data Bit: 8 / Stop Bit: 1
5. After connected, you will see a switch login request.
6. Login to the switch. The default username and password are
admin
.
Booting...
Switch login: admin
Password:
JetNet 4706 (version 2.1-20080409).
Copyright 2006-2008 Korenix Technology Co., Ltd.
Switch>