![Korenix JetNet 4508 V2 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/korenix/jetnet-4508-v2-series/jetnet-4508-v2-series_user-manual_1997846014.webp)
10
2.2 Wiring the Power Inputs
Follow below steps to wire JetNet 4508V2 /4508f V2 redundant DC power
inputs.
1. Insert positive and negative wires into V+ and V- contacts respectively of
the terminal block connector
2. Tighten the wire-clamp screws to prevent DC wires from being loosened.
3. Power 1 and Power 2 support power redundancy and polarity reverse
protect function. That means with wrong polarity, the system won’t work.
4.
Positive and negative power system inputs are both accepted, but Power
1 and Power 2 must apply with same mode as following figures.
Positive Power wiring
Negative Power wiring