Kontron DIMM-PC/MD Скачать руководство пользователя страница 6

DIMM-PC/MD Product Manual

Introduction

Kontron

® 

Embedded Modules GmbH

4

Revision 1.0

2.  INTRODUCTION

2.1   Kontron

  

DIMM-PC-Concept

It is likely that anyone who deals with micro-controller-development, has already thought
of the application of PC-architecture and considered the PC as the engine for an
application. However, most design engineers will get back to the old 87C51 or a similarly
more or less efficient micro-controller. The reasons why the Embedded PC was not yet
able to push away the micro-controllers from the printed boards, are many.

Embedded PCs are mechanically larger than a solution with a micro-controller.

The hardware of an Embedded PC is much more expensive than the micro-controller
solution.

The power consumption of an Embedded PC is usually higher than the one of a micro-
controller circuit.

A lot of times PCs have to be used with ribbon cables which are a possible cause of error.

Micro-controllers are available with a large number of peripheral functions, the PC,
however only has a standard periphery.

On the other hand there are some serious disadvantages of micro-controller solutions.

The software-development is much more complicated and expensive than under a
standard operating system.

Connection to standard-interfaces such as LANs and modems requires complicated driver
software.

Graphical user interfaces can be realized only by large programming efforts.

The development tools are by far not as powerful as PC-programming systems.

Micro-controllers do by far not have as many different PC-SW development tools
available.

This is why the purchase price is usually considerably higher for micro-controller
development tools.

Ready-made software solutions for standard tasks are only available in a very limited
extent.

The specified reasons are only a few of the more common ones, which are important in
deciding whether to implement a micro-controller or to change to PC-architecture.

Содержание DIMM-PC/MD

Страница 1: ...DIMM PC MD Product Manual Document Revision 1 0...

Страница 2: ...PT 4 3 FEATURES OF THE DIMM PC MODEM 6 4 BLOCK DIAGRAMM DIMM PC MODEM 7 5 MECHANICAL SPECIFICATION 8 5 1 ELECTRICAL SPECIFICATION 11 5 2 PERFORMANCE SPECIFICATION 12 5 3 ENVIRONMENTAL SPECIFICATIONS 1...

Страница 3: ...ess Machines XT AT PS 2 and Personal System 2 are trademarks of International Business Machines Corporation Microsoft is a registered trademark of Microsoft Corporation Intel is a registered trademark...

Страница 4: ...aware that your user specific settings were changed during the test Within the guarantee the repair is free as long as the guarantee conditions were held If no error has been found you will be charged...

Страница 5: ...ct documentation utilities and drivers If the information does not help to solve the problem contact us by email or telephone The table below lists Kontron technical support contacts and service facil...

Страница 6: ...bbon cables which are a possible cause of error Micro controllers are available with a large number of peripheral functions the PC however only has a standard periphery On the other hand there are som...

Страница 7: ...ife span is often ignored If the Embedded PC is to be implemented in today s micro controller applications the advantages of the PC architecture have to prevail compared to a micro controller solution...

Страница 8: ...features Low power CMOS technology 5V only power supply Signal pinning according DIMM PC specification Different selectable I O Addresses and IRQs Board size Modem module 68 x 40 mm 2 68 x 1 57 DAA mo...

Страница 9: ...iagramm DIMM PC Modem Kontron Embedded Modules GmbH 7 Revision 1 0 4 BLOCK DIAGRAMM DIMM PC MODEM The modem may be connected directly to the ISA BUS signals of the DIMM PC DAA Module DIMM PC MODEM DIM...

Страница 10: ...A10 58 MD14 59 SD9 60 MD13 KEY KEY 61 SYSCLK 62 MD12 63 SA11 64 65 SD8 66 67 REF 68 BLUE 69 SA12 70 GREEN 71 I2DAT 72 RED 73 SA13 74 VCC 75 I2CLK 76 VSYNC 77 SA14 78 GND 79 DRQ0 80 HSYNC 81 SA15 82 FP...

Страница 11: ...feedback for serial connected telephones In Germany Austria Switzerland France etc the telephone can be connected in serial In the USA UK etc the telephone will be connected in parallel a2 and b2 will...

Страница 12: ...ecification Kontron Embedded Modules GmbH 10 Revision 1 0 4mm R2 5mm R0 75mm R2mm 40mm 1mm 2 5mm 18mm 2mm 4mm 27 5mm 28 25mm side view front view 67 6mm gold plated gold plated free area on PCB for fu...

Страница 13: ...mbedded Modules GmbH 11 Revision 1 0 Mechanical Specification of the Modem DAA Modul top view side view 5 1 Electrical Specification Supply voltage 5V DC 5 Supply voltage ripple 150mV peak to peak 0 2...

Страница 14: ...Bell 212 V 32 V 32bis V 34 V 34 K56flex V 90 V 92 V 17 V 29 V 27ter and V 21 channel 2 Error correction and data compression MNP 2 4 V 42 LAPM MNP10 MNP 10EC Fax Group 3 Class1 Class1 0 Class2 Serial...

Страница 15: ...rating 40 C per hour Relative Humidity operating 10 90 RH non condensing non operating 5 95 RH non condensing Mechanical Shock 50G 20ms square wave maximum Vibration 1G 0 600Hz dwell not to exceed Alt...

Страница 16: ...rom any power supply The Modem Cards are delivered with settings adjusted to the IRQ5 and to I O address 3E8h If those configuration positions are already attributed to other cards then the hardware s...

Страница 17: ...FF OFF OFF OFF 2E0 ON OFF OFF OFF OFF OFF OFF OFF OFF IRQ 3 ON OFF OFF OFF 2E8 OFF ON OFF OFF OFF OFF OFF OFF OFF IRQ 4 OFF ON OFF OFF 2F0 OFF OFF ON OFF OFF OFF OFF OFF OFF IRQ 7 ON ON OFF OFF 2F8 OF...

Страница 18: ...transmission is supported including START and STOP bit For modem control just use a standard terminal program TELIX Procom etc For instance hyper terminal or similar can be used for Windows based PCs...

Страница 19: ...yntax 1 1 1 1 2 Command Descriptions 1 1 1 1 3 CaII Progressand Blacklisting Parameters 1 1 1 1 4 ConfigurACE II for Windows Utility Program 1 2 1 2 Reference Documentation 1 2 2 Syntax and Procedures...

Страница 20: ...nd Guidelines 3 1 3 1 1 Escape Code Sequence 3 1 3 2 Data Commands 3 1 3 2 1 Generic Modem Control 3 2 Z Soft Reset and Restore Profile 3 2 FCLASS Select Active Service Class 3 2 VCID Caller ID CID 3...

Страница 21: ...a Mode 3 37 L Speaker Volume 3 38 M Speaker Control 3 38 G Select Guard Ione 3 39 P Select Pulse DiaI Make Break Ratio 3 39 V Display Current Configuration and Stored Profiles 3 40 V1 Display Last Con...

Страница 22: ...3 78 DU Last CaIl Status Report 3 78 3 2 10 Compatibility Commands 3 86 L Leased Line Operation 3 86 M Enable Cellular Power Level Adjustment 3 86 M lnitial CelIular Power Level Setting 3 87 E Comprom...

Страница 23: ...pped Options Status 3 105 S28 Bit Mapped Options Status 3 106 S29 Flash Dial Modifierlime 3 106 S30 Disconnect lnactivity Timer 3 106 S31 Bit Mapped Options Status 3 107 S36 LAPM Failure Control 3 107...

Страница 24: ...er Enable 4 6 FAE Auto Answer Enable 4 7 FTS Transmit Silence 4 7 FRS Receive Silence 4 8 FTM Transmit Facsimile 4 9 FRM Receive Facsimile 4 10 FTH Transmit Data with HDLC Framing 4 11 FRH Receive Dat...

Страница 25: ...on 5 9 5 3 4 FET Transmit Page Punctuation 5 10 End a Page 5 10 5 3 5 FDR Begin or Continue Phase C Receive Data 5 11 lnitiate Document Reception 5 11 Continue Document Reception 5 12 Phase C Data Fra...

Страница 26: ...the DTE 6 2 6 1 2 DLE Shielded Codes Sent to the Modem DCE 6 3 6 2 Voice Commands 6 2 1 Configuration Commands 6 4 FCLASS 8 Select Voice Mode 6 4 VNH Automatic Hang up Control 6 4 6 2 2 Voice Commands...

Страница 27: ...e not supported 4 Try to get as much information about the malfunction as possible before asking for support is the modem visible in the setup summary screen does the settings of your terminal program...

Отзывы: