cPCI-MXS64GX Technical Reference Manual

F-2

F.3 

E

RROR 

M

ESSAGES

One or more of the following messages may be displayed if the BIOS detects an error
during the POST. This list includes messages for both the ISA and EISA BIOS.

CMOS BATTERY HAS FAILED

1.

If it’s the first boot, check for the onboard battery jumper (jumper W4 for both the 
cPCI-MXS64GX). The board is shipped with W4 jumper set to OFF (onboard battery 
disconnected). This jumper must be shorted (ON) for proper battery operation.

2.

CMOS battery is no longer functional. It should be replaced.

CMOS CHECKSUM ERROR

Checksum of CMOS is incorrect. This indicates that CMOS has become corrupt. A weak
battery may have caused this error. Check the battery and replace if necessary.

DISK BOOT FAILURE, INSERT SYSTEM DISK AND PRESS ENTER

No boot device was found. This could mean either a boot drive was not detected or the
drive does not contain proper system boot files. Insert a system disk into Floppy Drive A
and press Enter. If you assumed the system would boot from the hard drive, make sure the
controller is inserted correctly and all cables are properly attached.  Also be sure the disk is
formatted as a boot device. Then reboot the system.

KEYBOARD ERROR OR NO KEYBOARD PRESENT

Cannot initialize the keyboard. Make sure the keyboard is attached correctly and no keys
are being pressed during the boot.
If you are purposely configuring the system without a keyboard, set the error halt condition
in Setup to HALT ON ALL, BUT KEYBOARD. This will cause BIOS to ignore the
missing keyboard and continue the boot.

OFFENDING SEGMENT

This message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY
ERROR messages when the segment that has caused the problem cannot be isolated.

PRESS F1 TO DISABLE NMI, F2 TO REBOOT

When BIOS detects a Non-maskable Interrupt condition, this will allow you to disable the
NMI and continue to boot, or you can reboot the system with the NMI enabled.

Содержание cPCI-MXS64GX

Страница 1: ...n com Note The latest releases of the Technical Reference Manuals are available at ftp ftp kontron ca Support Product_Manuals cPCI MXS64GX 6U CompactPCI 64 BIT System Processor Technical Reference Man...

Страница 2: ...J3 for J5 Added line The infrared COM2 signals COM2_IRRX and COM2_IRTX are available at J3 connector Page 2 11 In table signal path description Removed the line In Infrared mode signals are available...

Страница 3: ...ion location J5 COM1 2 J3 COM 3 4 Infrared Replace in section E 4 connector J3 RowD Pin14 SD8 by SD8 Remove BMC IPMI support and references Replace in section E 2 J1 BMC Xlinx C17 IPMB0_SDA by I2C_SDA...

Страница 4: ...with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will...

Страница 5: ...of information or the use of products described herein This document may contain information or refer to products protected by the copyrights or patents of others and does not convey any license under...

Страница 6: ...facturer s instructions ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Remplacer uniquement avec une batterie du m me type ou d un type quivalent recommand par le c...

Страница 7: ...this is the minimum required to see if the board is working If you still are not able to start up your system please refer to the emergency Procedure in the Appendix Section If you still are not able...

Страница 8: ...vices Do not handle or store devices near strong electrostatic electromagnetic magnetic or radioactive fields Power Supply Before any installation or setup ensure that the board is unplugged from powe...

Страница 9: ...2 Mezzanine 1 6 1 5 Compatibility with other KONTRON Products 1 7 1 6 Mezzanine Card Concept 1 8 1 6 1 Kontron s Mezzanine Concept 1 9 1 6 2 PMC Concept 1 9 1 6 3 CompactFlash Feature 1 9 2 ONBOARD F...

Страница 10: ...2 9 1 SERIAL PORT 1 2 9 2 9 1 1 Remote Reset 2 9 2 9 1 2 Front Plate Configuration 2 10 2 9 2 Serial Port 2 2 10 2 9 3 Serial Port 3 2 10 2 9 3 1 Infrared Mode 2 11 2 9 3 2 RS 232 Protocol 2 12 2 9 3...

Страница 11: ...ion 3 4 3 1 8 Uart 4 PnP configuration 3 5 3 1 9 Digital watchdog 3 5 3 1 10 NMI control 3 6 3 1 11 0Register BITs description summary 3 7 3 2 Onboard Interconnectivity 3 8 3 2 1 cPCI MXS64GX Block Di...

Страница 12: ...ervision Features 3 19 3 3 4 1 Power Fail Monitoring 3 19 3 3 4 2 Watchdog 3 20 3 3 4 3 Thermal Management 3 22 3 4 Building a CPCI System 3 23 3 4 1 Backplane 3 24 3 4 2 Rear Panel I O 3 25 3 4 3 Sto...

Страница 13: ...pecification 3 32 3 5 2 1 Power Management 3 32 3 5 2 2 SCSI Interface 3 32 3 5 2 3 Video Interface 3 33 3 5 2 4 Ethernet 1 Interface 3 33 3 5 2 5 Hot Swap HA High Availability signals 3 33 3 5 2 6 ID...

Страница 14: ...4 5 4 1 5 Saving Exiting Operations 4 5 4 1 6 BIOS Features Setup 4 6 4 1 7 Chipset Features Setup 4 8 4 1 8 Power Management Setup 4 10 4 1 9 PnP PCI Configuration 4 12 4 1 10 CPU Board Features Setu...

Страница 15: ...B 2 C INTERRUPT LINES C 1 C 1 IRQ Lines C 1 C 2 DMA Channels C 1 D BOARD DIAGRAMS D 1 D 1 Top Devices Surface Mount D 1 D 2 Assembly Bottom Diagram D 2 D 3 Mounting Holes D 3 D 4 Connector Holes D 4...

Страница 16: ...Disk E 8 E 13 J19 Storage mezzanine E 9 E 14 J20 PMC E 10 E 15 J21 PMC E 11 E 16 Hot Swap Switch E 12 E 17 S1 Reset Switch E 12 E 18 BT1 CMOS Battery Backup Connector E 12 F BIOS SETUP ERROR CODES F...

Страница 17: ...1 PRODUCT DESCRIPTION 1 PRODUCT OVERVIEW 2 SPECIFICATIONS 3 HOT SWAP CAPABILITY 4 INTERFACING WITH THE ENVIRONMENT 5 COMPATIBILITY WITH KONTRON PRODUCTS 6 MEZZANINE CONCEPTS 1 PART...

Страница 18: ...parent bridge the feature set of the cPCI MXS64GX includes a rich selection of standard peripherals The cPCI MXS64GX offers a natural growth path to high performance high availability as well as hot s...

Страница 19: ...et Four serial ports three RS 232 only Serial Port 1 2 and 4 one RS 232 422 485 Serial Port 3 One Parallel port bi directional with all IEEE 1284 protocols supported with BIOS selectable IRQs and addr...

Страница 20: ...and Green support Hardware monitor voltages temperature and fan speed Power failure circuit Two year warranty The cPCI MXS64GX can be purchased either for front plate I O interfacing video serial port...

Страница 21: ...ible through the use of different pin lengths and the process ends with the mating of the shortest pin BD_SEL The platform adds hardware to provide more control of each board s Hardware Connection Lay...

Страница 22: ...board This LED indicates that system software has been placed in a state for orderly extraction of the board The hardware connection layer provides protection only for the hardware during insertions a...

Страница 23: ...J3 J5 B In Rear I O configuration all I O signals are connected to J3 J5 A backplane dedicated to the cPCI MXS64GX is provided by Kontron and is referred to as cBP08R CPCI Passive Backplane 1 4 2 Mez...

Страница 24: ...anine card with hard disk and floppy disk drive cMCB Mezzanine card with bridge hard disk and floppy disk cSM DVDHD Storage module with DVD and Hard Disk cSM DVD Storage module with DVD only CxP0816 i...

Страница 25: ...hnical Reference manual 1 8 1 6 MEZZANINE CARD CONCEPT The capability of the cPCI MXS64GX to connect with other devices is enforced by PCI Mezzanine Cards PMC A fully equipped cPCI MXS64GX board may a...

Страница 26: ...ces The cPCI MXS64GX features the PMC concept onboard to provide an extra method to support the 32 bit I O devices available on the market PMC devices connect directly to standard PMC connectors A mec...

Страница 27: ...2 ENHANCED IDE INTERFACES 3 ETHERNET INTERFACES 4 FLOPPY DISK INTERFACE 5 PS 2 KEYBOARD AND MOUSE INTERFACE 6 PARALLEL PORT 7 POWER MANAGEMENT 8 SCSI INTERFACE 9 SERIAL PORTS 10 THERMAL MANAGEMENT 11...

Страница 28: ...disk connects on the cPCI MXS64GX via the onboard Flash Disk connector Related Jumpers cPCI MXS64GX W3 to set the CompactFlash disk as master or slave BIOS Settings Section 4 1 2 Main Menu Hard Disk a...

Страница 29: ...ector The secondary IDE interface is only available through the CPCI I O connector Related Jumpers None BIOS Settings Section 4 1 11 Integrated Peripherals The IDE interfaces supports PIO mode 4 trans...

Страница 30: ...speeds are automatically detected and switched Signal Path See note on page 1 5 Related Jumpers None BIOS Settings Section 4 1 11 Integrated Peripherals Enable Disable Ethernet Controller 2 3 1 Front...

Страница 31: ...twork Drivers for Intel 82559 is included with the cPCI MXS64GX It contains network drivers for most common operating systems 2 4 FLOPPY DISK INTERFACE The onboard floppy disk controller is IBM PC XT...

Страница 32: ...signals are available through J5 CPCI I O connector and J14 Mezzanine connector Related Jumpers None BIOS Settings 11 3 7 Integrated Peripherals USB Keyboard Support PS 2 Mouse Function Control 2 6 PA...

Страница 33: ...PD5 PD5 A16 PD6 PD6 PD6 E15 PD7 PD7 PD7 1 Compatible mode 2 High Speed Mode NOTE To operate in EPP or ECP mode ensure the peripheral is designed to work in this mode and the BIOS setup is configured t...

Страница 34: ...ode when addressing multiple logical devices in a single physical product While the EPP mode may intermix read and write operations without any overhead or protocol handshaking the ECP mode negotiates...

Страница 35: ...nabled through the AWARD BIOS setup program 2 9 SERIAL PORTS Four full function serial ports are provided on the board for asynchronous serial communications They are 16C550 high speed UART compatible...

Страница 36: ...ial Port 2 or disabled BIOS Settings Section 4 1 11 Integrated Peripherals Enable Disable Onboard FDC Controller Select Com Port Address of Serial Port 1 2 9 1 1 Remote Reset A remote hardware reset o...

Страница 37: ...l Port 1 signals are available through a DB 9 connector located on the front plate CPCI I O Configuration The complete signal set is tied to the J5 CPCI I O connector to be used through the Rear Trans...

Страница 38: ...grated Peripherals Onboard Serial Port 3 Serial Port 3 Mode Upon a power up or reset the Serial Port 3 interface circuits are automatically configured for the operation mode setup in the BIOS The Seri...

Страница 39: ...ls during a communication session It differs from the RS 422 mode as it offers the ability to transmit and receive over the same pair of wires and allows the sharing of the communication line by multi...

Страница 40: ...ible with the IBM AT serial port Signal Path Serial Port 4 signals are only available through the J3 CPCI I O connector Related Jumpers None BIOS Settings 11 3 7 Integrated Peripherals Onboard Serial...

Страница 41: ...speed will be slowed down as soon as the ambient temperature reaches the high ambient temperature value Thermal management operations are controlled by the GX chipset and settings are provided throug...

Страница 42: ...1280 x 1024 x 256 colors The video interface features 64 bit 2D graphics engine 64 bit GUI accelerator engine with multiple window video acceleration Signal Path The VGA video signal path depends on...

Страница 43: ...million 24 bits 640x480 800x600 16 8 million 32 bits 2 12 2 Major Features Description VGA Compatibility The video controller includes all registers and data paths required for VGA controller and supp...

Страница 44: ...3 INSTALLING THE BOARD 1 SETTING JUMPERS 2 REGISTER S DESCRIPTION 3 ONBOARD INTERCONNECTIVITY 4 CUSTOMIZING THE BOARD 5 BUILDING A CPCI SYSTEM 6 CPCI I O SIGNALS 3 PART...

Страница 45: ...figuration W3 Onboard Battery Connects or Disconnects the battery to from the board circuitry W4 Remote Reset To select Serial Port 1 or Serial Port 2 as a source for the remote hardware reset W5 SCSI...

Страница 46: ...pact Flash Disk W4 Battery RS 422 485 modes only With termination Without termination W8 W9 COM2 Terminations DS1 1 1 4HP Configuration 8HP Configuration Connected Disconnected Enable VT 100 mode Rese...

Страница 47: ...n The serial port 2 mode can be controlled by setting three bits Here are the possibilities Mode Bit RS485 Bit RS232 Bit ST1 RS232 0 1 X RS422 1 0 0 RS485 1 0 1 X Don t care 3 1 4 History and monitor...

Страница 48: ...ccess CPLD Address D7 D6 D5 D4 D3 D2 D1 D0 READ n93h NU NU NU NU IDCHIP NU I2C_CLK I2C_DATA WRITE n93 h NU NU NU NU IDCHIP NU I2C_CLK I2C_DATA Power up Default 0 0 0 I2C_DATA I2C data I2C_CLK I2C Cloc...

Страница 49: ...Address D7 D6 D5 D4 D3 D2 D1 D0 READ n95 CND4 CIS4_1 CIS4_0 CBAS4_ 1 CBAS4_0 WRITE n95 CND4 CIS4_1 CIS4_0 CBAS4_ 1 CBAS4_0 NU Power up Default 0 0 0 1 1 CND4 When low decode the base address CIS4_ 1...

Страница 50: ...65536T NMI T 8T 111 262144T NMI T 8T Time out selection with T 1 08ms TBC 3 1 10 NMI control CPLD Address D7 D6 D5 D4 D3 D2 D1 D0 READ n97 BATFEN BATFLT NU NU NU NU WDNMIEN WDNMI WRITE n97 BATFEN NU...

Страница 51: ...IS3_1 CIS3_0 CBAS3_1 CBAS3_0 RESERVED READ RESERV n95 WRITE _CND4 CIS4_1 CIS4_0 CBAS4_1 CBAS4_0 NU NU READ n96 WRITE WDEN WDD2 WDD1 WDD0 NU READ BATFLT WDNMI n97 WRITE BATFEN NU NU WDNMIEN NU READ n98...

Страница 52: ...nectors Arbiter SYM53C895 LVD SCSI Term System Clock Intel CuMine PIII MPIII Core 500Mhz GTL XTAL XTAL EEPROM EEPROM 82559 100Base T Ethernet 1 RJ 45 RJ 45 PCI Kontron s Mezzanine CPCI J3 J4 XTAL EEPR...

Страница 53: ...KB on die full CPU speed ECC capable and a 64 bit high performance 100MHz front side bus The processor interfaces to the 440GX AGPset through the 64 bit low power GTL data bus interface 3 2 3 North Br...

Страница 54: ...s is busy This traffic isolation may increase system performance in applications where system resources are highly used 3 2 5 82371AB PCI to ISA Bridge IDE Xcelerator PIIX4 The PCI to ISA bridge is co...

Страница 55: ...ector VGA J12 Supports standard 15 pin DSUB female connector Serial Port 1 J13 Supports standard 9 pin DSUB male connector Kontron s Mezzanine J14 J19 This connector handles PCI bus signals to the mez...

Страница 56: ...vity on IDE SCSI devices Indicate a board failure ready to swap J13 Com Port 1 Standard 9 pin DSUB male connector J16 J15 Ethernet 1 and 2 RJ 45 connectors with built in activity and link indicators J...

Страница 57: ...3 2 8 FACEPLATE OPTIONS 1 15 1 5 6 9 1 3 5 4 2 6 1 1 15 1 5 6 9 1 3 5 4 2 6 1 15 1 5 6 9 1 3 5 4 2 6 4HP Front Access 4HP Rear Access 8HP Front Access 8HP Front Access with Floppy 8HP Rear Access 8HP...

Страница 58: ...eset USB SMBus and power signals CPCI J4 Connector Supports Ethernet1 secondary IDE channel SCSI VGA and power signals CPCI J3 Connector Supports serial ports 3 4 Infrared V Port Ethernet1 and power s...

Страница 59: ...ponents particular attention should be given while installing a processor on the board Improper installation may damage the board and or the CPU CAUTION Since CPUs are very sensitive components partic...

Страница 60: ...backup BIOS setup values and the real time lock RTC When replacing the battery must be connected as follows WARNING Danger of explosion if battery is incorrectly replaced Replace only with the same or...

Страница 61: ...resence Detect SPD EEPROM Errors Checking and Correction ECC capabilities or parity bit with 72 bit modules Compliant with Intel s PC SDRAM Unbuffered DIMM Specification 100MHz Rev 1 0 At least 32MB o...

Страница 62: ...ENTON CTK256M P100S ECC SDRAM 256MB 32M 72 PC100 1 15 CENTON DIM203272VDS08GS ECC SDRAM 256MB 32M 72 PC100 1 15 SHIKATRONICS VM374S3323 GL ECC SDRAM 256MB 32M 72 PC100 1 15 VIRTIUM 3 3 3 2 DIMM Instal...

Страница 63: ...board battery When the battery is in a low condition below 2 9V typical the PFO power fail output signal goes low The status of the PFO signal can be read at I O address 4031h bit 1 0 failed 1 good An...

Страница 64: ...learing the lock bit in register 0x92h bit 2 then set th4e bit WDEN bit 7 in register n92h and relock it by setting the lock bit in register 0x92 bit 2 The following is an example in C language define...

Страница 65: ...rom reaching count 0 timeout The following C language procedure can be used to trigger the programmable watchdog define TekReg 0x190 define base address 0x190 0x290 or 0x390 void TrigWatchdog timeout...

Страница 66: ...6s 1ms 001 0 065s 0 065s 1ms 010 0 261s 0 261s 1ms 011 1 044s 1 044s 1ms 100 4 174s 4 174s 1ms 101 16 69s 16 69s 1ms 110 66 79s 66 79s 1ms 111 267 1s 267 1s 1ms A reset from the programmable watchdog...

Страница 67: ...ent consists in a chassis a CompactPCI backplane a storage module a power supply unit and a ventilation system The main AC power is drawn to the chassis components through an IEC power plug with a 2 s...

Страница 68: ...s driven directly by the system processor while the other is managed through a PCI to PCI bridge implemented on the cMCB 2RC mezzanine card Storage PCI to PCI mezzanine All Kontron s CompactPCI backpl...

Страница 69: ...ear of the enclosure using a Rear I O Transition module cTM80 STD2S The Rear I O Transition module gathers all the I O signals of the CPU board and makes them easily accessible through standard header...

Страница 70: ...cPCI MXS64GX Technical Reference Manual 3 26 1 Rev...

Страница 71: ...d 3 4 5 Fan Tray The ventilation unit of the enclosure conforms to the global requirement of the system in fully loaded configuration 3 4 6 Installing the Board into a Bay The cPCI MXS64GX is mechanic...

Страница 72: ...ation Color coded keys prevent inadvertent installation of a 5V peripheral board in a 3 3V slot The cPCI MXS64GX is universal It does not support coding key The PCI bus does not require to be keyed Ba...

Страница 73: ...connector WARNING 1 Some mechanical parts of the guide rail are fragile shield contacts and clips Do not use force to insert and connect a CompactPCI module 2 If there is any mechanical resistance whi...

Страница 74: ...signal ACTLED 0 1 C6 A7 Transmit receive activity LED signal 3 5 1 2 Ethernet 1 Signal Pin Assignation Description ETX 1 A9 Ethernet High Transmit Data line ETX 1 B9 Ethernet Low Transmit Data line E...

Страница 75: ...rt 2 IRRX D18 IR receive data line Serial Port 2 Serial Port 2 IRTX E18 IR transmit data line Serial Port 2 3 5 1 7 Hot Swap HA High Availability signals Signal Pin Assignation Description BDSEL S2 S5...

Страница 76: ...indicate a byte is ready or is needed by the Target CD C3 Command Data Indicates Command or message phase when asserted and Data phase when not asserted SSEL D3 SCSI Select The line is driven after a...

Страница 77: ...ace Signal Pin Assignation Description ETX 0 A16 Ethernet 1 High Transmit Data line ETX 0 B16 Ethernet 1 Low Transmit Data line ERX 0 C16 Ethernet 1 High Receive Data line ERX 0 D16 Ethernet 1 Low Rec...

Страница 78: ...de this is the command to the IDE device that it may drive data on SDD lines SIORDY B22 Sec I O Channel Ready In normal mode this input signal is driven directly by the corresponding IDE device IORDY...

Страница 79: ...on SDD lines PIORDY B5 Prim I O Channel Ready In normal mode this input signal is driven directly by the corresponding IDE device IORDY signal PDDACK D5 Prim DMA Acknowledge This signal directly driv...

Страница 80: ...C10 Read disk data FD HDSEL D10 Head select FD DSKCHG E10 Disk change 3 5 3 4 Serial Port 2 Signal Pin Assignation Description JDCD2 A11 Data Carrier Detect JRXD2 C11 Receive Data JDSR2 D11 Data Set R...

Страница 81: ...Error at printer STB A19 Strobe signal 3 5 3 7 Miscellaneous Signals Signal Pin Assignation Description SMBDATA B20 Onboard SMbus data SMBALERT C20 Onboard SMbus Alert CPU overheating SMBCLK E20 Onbo...

Страница 82: ...4 SOFTWARE SETUPS 1 BIOS SETUP PROGRAM 2 VT100 MODE 4 PART...

Страница 83: ...om LAN utility this utility is located on the driver s CDROM 4 1 1 Accessing the BIOS setup program The system BIOS Basic Input Output System provides an interface between the operating system and the...

Страница 84: ...may refer to the list of default values The list of defaults is provided in the event that a value has been changed and one wishes to set this option to its original value Loading the BIOS or SETUP d...

Страница 85: ...herals controller in your system Load Bios Defaults The BIOS defaults are fail safe settings which consist of the safest set of parameters Use them if the system is behaving erratically They should al...

Страница 86: ...isplayed when you entered the program When in BIOS Features Setup Chipset Features Setup Power Management Setup PNP PCI Setup or Integrated Peripherals Setup Restores the previous setup values for tha...

Страница 87: ...pe of display adapter card installed in the system Halt on This option specifies the type of errors that will stop the system during the BIOS booting procedure A message asks that you press F1 to cont...

Страница 88: ...your logo being displayed contact the Technical Support see appendix G Boot from LAN First Dis Dis En Dis If Enabled the BIOS will first attempt to boot from the LAN The complete procedure for this f...

Страница 89: ...or All All All Supervisor When this option is set to Supervisor and the Security option to System all floppy disk accesses read write are limited to the Supervisor supervisor password required Boot Up...

Страница 90: ...ampled by the SDRAMs and when the chipset samples read data from the SDRAMs Select 3 for 3 DCLKs and 2 for 2 DCLKs If a given row is populated with a registered SDRAM DIMM an extra clock is inserted b...

Страница 91: ...s option selects the type of power supply AGP Aperture Size MB 64 64 4 to 256 This option selects the size in megabytes of the AGP Aperture Video BIOS Shadow En En En Dis C8000 CBFFF En En En Dis CC00...

Страница 92: ...s to the video buffer Video Off After Standby Standby NA Suspend Standby Doze As the system moves from lesser to greater power saving modes select the mode in which you want the monitor to blank Doze...

Страница 93: ...En Dis When Enabled allows setup of a time to re activate the CPU when in Suspend mode with the options Date of Month Alarm and Time hh mm ss Alarm Note The IRQ 8 Break Suspend option in this setup s...

Страница 94: ...ific interrupt PCI ISA PnP Devices compliant with the Plug and Play standard whether designed for PCI or ISA bus architecture When Legacy ISA is selected for an IRQ line this resource will not be avai...

Страница 95: ...larm C temperature Full speed Normal mode will be resumed when the temperature comes down to the selected Resume Alarm C temperature A minimum of 4 is automatically ensured for the Overheat Alarm temp...

Страница 96: ...sables the onboard SCSI controller Ethernet Controller 1 and 2 En En En Dis Enables disables the onboard Ethernet controller USB Keyboard Support OS OS OS BIOS This option is for DOS and BIOS support...

Страница 97: ...turn on the power 2 Enter into the CMOS Setup program in the BIOS Feature Setup 3 Select the VT100 mode and the appropriate COM port and save your setup 4 Connect the communications cable as shown in...

Страница 98: ...o terminal is connected the speed is set to 115 200 bauds Furthermore you can run without any console at all by simply not enabling VT100 Mode and by disabling the onboard video RXD TXD DSR DTR CTS RT...

Страница 99: ...APPENDICES A BOARD SPECIFICATIONS B MEMORY I O MAPS C INTERRUPT LINES D BOARD DIAGRAMS E CONNECTOR PINOUTS F BIOS SETUP ERROR CODES G EMERGENCY PROCEDURE H GETTING HELP RMA 5 PART...

Страница 100: ...ers and power control Cache Memory cPCI MXS64GX Level 1 16 16KB instruction Data CPU internal Level 1 Level 2 256KB internal 64 bit wide pipelined burst System Memory Three 168 pin Latching DIMM socke...

Страница 101: ...et 1 and 2 2 x RJ 45 with built in LEDs PS 2 mouse Keyboard 6 pin mini DIN Interfaces on J3 J4 J5 Rear CPCI I O Connectors J3 J4 J5 Rear panel transition module cTM80 STD2S available separately CRT Se...

Страница 102: ...wo channel Bus Master PCI EIDE support for four IDE Type 4 drives master slave configuration LBA PIO Mode 0 4 and Ultra DMA 33 CompactFlash Optional bootable CompactFlash disk interfaces to primary EI...

Страница 103: ...ccess Software enable disable of onboard Ethernet SCSI hardware enable disable of onboard video Diskless keyboardless and videoless operation extensions System video SCSI LAN and extension BIOS shadow...

Страница 104: ...titude 4 572m 15 000 ft 15 240m 50 000ft Shock Designed to meet IEC 68 2 27 Vibration Designed to meet IEC 68 2 6 Reliability MTBF cPCI MXS64GX 54810 hours 20 C MIL HDBK 217F Board serial number in EE...

Страница 105: ...no device address may vary E0000 FFFFF System BIOS 100000 Top of DRAM 1 MB Top of DRAM 1MB to top of DRAM System BIOS See detailed map to the right 0 640KB DRAM Optional ROM Free SCSI BIOS 18KB at ru...

Страница 106: ...nterrupt Controller 2 0C0 0DF DMA Controller 2 0F0 0F1 0F8 0FF Math Coprocessor 190 197 290 297 390 397 Kontron Control Port 1F0 1F7 3F6 Primary IDE 170 177 376 Secondary IDE 3F0 3F7 370 377 Floppy Di...

Страница 107: ...or available 1 All functions marked with an asterisk can be disabled or reconfigured 1 Available lines service on board and external PCI ISA PnP devices or a Legacy ISA device C 2 DMA CHANNELS The cP...

Страница 108: ...D 1 D BOARD DIAGRAMS D 1 TOP DEVICES SURFACE MOUNT...

Страница 109: ...cPCI MXS64GX Technical Reference Manual D 2 D 2 ASSEMBLY BOTTOM DIAGRAM...

Страница 110: ...Board Specifications D 3 D 3 MOUNTING HOLES...

Страница 111: ...ECTOR HOLES 8 971 8 734 8 459 7 759 6 494 4 636 4 084 3 892 3 659 3 374 0 000 0 216 0 140 0 000 0 103 0 180 0 510 2 935 4 630 5 025 5 420 6 100 6 159 0 000 0 059 1 909 3 309 3 669 5 191 7 159 0 000 0...

Страница 112: ...ront panel configuration only J13 Serial Port 1 RS 232 Front panel configuration only J14 Mezzanine PCI Connector J15 Ethernet 1 Connector Front panel configuration only J16 Ethernet 2 Connector Front...

Страница 113: ...I O AD25 AD24 9 CBE3 RSB AD23 GND AD22 10 AD21 GND VCC3E AD20 AD19 11 AD18 AD17 AD16 GND CBE2 12 13 14 KEY AREA 15 VCC3E FRAME IRDY BD_SEL TRDY 16 DEVSEL GND V I O STOP LOCK 17 VCC3E I2C_SCL I2C_SDA...

Страница 114: ...60 7 AD59 GND V I O AD58 AD57 8 AD56 AD55 AD54 GND AD53 9 AD52 GND V I O AD51 AD50 10 AD49 AD48 AD47 GND AD46 11 AD45 GND V I O AD44 AD43 12 AD42 AD41 AD40 GND AD39 13 AD38 GND V I O AD37 AD36 14 AD35...

Страница 115: ...KLED_1 SPEEDLED1 7 ACTLED_1 SD7 SD6 SD5 SD4 8 GND VCC VCC SD3 SD2 9 ETX 1_1 ETX _1 ERX _1 ERX _1 GND 10 GND WR_80 SD1 12V 12V 11 JDCD4 GND RJXD4 JDSR4 JTXD4 12 JRTS4 JCTS4 JR14 VCC JDTR4 13 JDCD3 VCC...

Страница 116: ...4 SD13 SD12 9 SRST SMSG S5HEALTHY R_VSDA S5PCIRST 10 R_VSCL R_SYNC V_SYNC R_RED R_GREEN 11 R_BLUE SD3 S6BDSEL SD5 SD6 12 13 14 KEY AREA 15 SD0 5V 5V S6HEALTHY S6PCIRST 16 ETX _0 ETX _0 ERX 0 ERX 0 SD7...

Страница 117: ...FD_WRTP RT FD_RDATA FD_HDSEL FD_DSKCHG 11 DCD2 GND RXD2 DSR2 TXD2 12 RTS2 CTS2 RI2 VCC DTR2 13 DCD1 VCC RXD1 DSR1 TXD1 14 RTS1 CTS1 RI1 GND DTR1 15 LPT_SLCT LPT_PE LPT_BUSY LPT_ACK LPT_D7 16 LPT_D6 LP...

Страница 118: ...BD_SEL MS3_HEALTHY MS3_PCI_RST GND 12V 12V PBRST AD2 GND AD7 AD9 VCC AD13 C BE1 GND PERR VCC3 TRDY GND AD16 VCC3 AD20 AD23 GND C BE3 AD26 VCC AD30 GND MS8_PCI_RST VCC PCLK_MEZ VCC INTA INTB ENUM MS4_B...

Страница 119: ...3 4 5 6 E 12 J18 COMPACTFLASH DISK Pin Number Top View Pin Number Signal Signal D11 D12 D13 D14 D15 CS1 dmack dma_req PDIAG IRQ VCC GND RESET CSEL A1 A0 D0 D1 D2 IOCS16 1 3 5 7 9 11 13 15 17 19 21 23...

Страница 120: ...STEP FD GATE FD WRTPTR FD HSEL VCC VCC MDATA KBCLK GND GND GND GND GND FD DRVEN0 FD MTR1 FD DS0 FDET FD DIR FD WDATA FD TRK0 FD RDATA 12V VCC VCC PDD1 PDD3 PDD5 PDD7 PDD9 PDD11 PDD13 PDD15 PDIOW PIOR...

Страница 121: ...D SDONE PAR VCC AD12 AD9 GND AD6 AD4 VCC AD2 AD0 GND 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40...

Страница 122: ...d Not Connected GND Not Connected GND 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50...

Страница 123: ...Reference Manual E 12 E 16 HOT SWAP SWITCH Signal Top View VCC3E SW_OPEN GND 1 2 3 E 17 S1 RESET SWITCH Signal View RESET GND 1 2 E 18 BT1 CMOS BATTERY BACKUP CONNECTOR Signal Front View Battery Batt...

Страница 124: ...IOS checksum error 22 Error when getting the boot block flash ID code 33 Error when erasing the boot block flash 44 Error when programming the boot block flash 55 Success of the boot block recovery co...

Страница 125: ...drive does not contain proper system boot files Insert a system disk into Floppy Drive A and press Enter If you assumed the system would boot from the hard drive make sure the controller is inserted c...

Страница 126: ...lt show POST BEh 09 Early Cache Initialization 1 Check for Intel s and or Cyrix CPU 2 Early Cache Initialization when cache is separate from chipset 3 Turn off Gate A20 0A Setup Interrupt Vector Table...

Страница 127: ...ation 14h to find out type of video to use Detect and initialize Video Adapter 12 Init T380 if necessary Boot Block in EMERGENCY Try to init Video Card 0E Test Video Memory 1 If CGA or MONO test video...

Страница 128: ...de NOTE 2 This POST also Detect Report I O PORTS and also Init Super IO 33 3C Reserved Reserved 3C Setup Enable 3D Initialize Install PS 2 Mouse Detect if mouse is present Initialize mouse Install int...

Страница 129: ...Kontron block have a valid CRC If not the Emergency procedure is launched 85 AF Reserved Reserved B0 Spurious If interrupt occurs in protected mode B1 Unclaimed NMI If unmasked NMI occurs display Pre...

Страница 130: ...speed mode D1 Power Management Doze mode Trying to go or in Doze mode D2 Power Management Sleep mode Trying to go or in Sleep mode D3 Power Management Suspend mode Trying to go or in Suspend mode D4 D...

Страница 131: ...Y PROCEDURE proceed as follows 1 Remove battery jumper 2 Disable the Power Fail Detection function 3 Connected a 1 44MB floppy drive drive A to the board and insert the EMERGENCY diskette that you pre...

Страница 132: ...K then press Enter key 5 The program may display one of the following messages Emergency Code transferred The emergency diskette has been successfully created Take the appropriate actions and restart...