![Kontron cPCI-MXS64GX Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/kontron/cpci-mxs64gx/cpci-mxs64gx_technical-reference-manual_1996276124.webp)
F-1
F. BIOS SETUP ERROR CODES
F.1
POST B
EEP
POST beep codes are defined in the BIOS to provide low level tone indication when an
error occurs during the BIOS initialization.
Beep codes consist of a combination of long and short beeps. They are described as
follows:
Beep Codes
Post code
Beep Code
Description
41
**-*
Enterring the boot block recovery code (i.e. Main BIOS
checksum error)
22
*-*-*
Error when getting the boot block flash ID code
33
*-*-*-*
Error when erasing the boot block flash
44
*-*-*-*-*
Error when programming the boot block flash
55
*-*
Success of the boot block recovery code. The board is ready
to be manually reset.
Legend
* = 1 Short beep code, ** = 1 Long beep code, - = Silence
F.2
POST M
ESSAGES
During the Power On Self Test (POST), if the BIOS detects an error requiring you to do
something to fix, it will either sound a beep code or display a message.
If a message is displayed, it will be accompanied by: