2-18
AT8001 User’s Guide
UART registers are individually addressable and fully programmable.
2.3.5.1
Serial Port 1 (J5)
Serial Port 1 is buffered directly for RS-232 operation. Signals include the complete signal set for
handshaking, modem control, interrupt generation, and data transfer. When assigned as Serial Port
1, the port is 100% compatible with the IBM-AT serial port in RS-232 mode.
Note:
Standard product uses a RJ-45 8 pins connector. RI (ring indicator) and DCD (data carrier detect)
signals are not available.
Optionally a RJ-45 10 pins connector may be populated which allow to use RI and DCD. Contact
Kontron’s technical support if you are interested with this option.
The pinout is a custum one, not the same as RS-232D EIA-561. Use the Kontron provided RJ45 to
DB9 adapter.
Signal Paths:
The Serial Port 1 signal is always available in front and rear access.
Bios Settings:
Advanced
Æ
SuperIO Configuration
Æ
ICH SIO Serial Port1 Address.
2.3.5.2
Serial Port 2
Serial Port 2 is internally connected to the IPMC. Serial port 2 is dedicated to Serial Over LAN (SOL)
type of console redirection. (This feature will be implemented shortly)
2.3.6
Real Time Clock & NVRAM
The AT8001 is a battery less board. The real time clock and non-volatile RAM integrated in the
6300ESB ICH are powered by the main supply when available or by a double layer SuperCap when the
main power is absent. The SuperCap will keep the real time clock running for a couple of hours.
Pin
Signal
1 RTS
2
DTR
3 TXD
4
GND
5 GND
6
RXD
7 DSR
8
CTS
Содержание AdvancedTCA AT8001
Страница 1: ...AT8001 User s Guide AdvancedTCA Document Revision 1 0 Ref M5002_TECH_1 July 2005 ...
Страница 28: ...2 10 AT8001 User s Guide 2 1 Block Diagram ...
Страница 59: ...3 2 AT8001 User s Guide 3 1 2 Setting Jumper locations ...
Страница 67: ...4 0 AT8001 User s Guide 4 Building an ATCA System Contents 4 1 Building an ATCA System 4 1 ...