![Kontron AdvancedTCA AT8001 Скачать руководство пользователя страница 111](http://html.mh-extra.com/html/kontron/advancedtca-at8001/advancedtca-at8001_user-manual_1996242111.webp)
B-6
AT8001 User’s Guide
REFSEL
Show the reference that is currently selected.
0: Primary reference
1: Secondary reference
RSV1/ RSV0
Reserved.
B.11
0A0AH: TELCLOCK2 (TELECOM CLOCK OPTION)
Address
Action
D7
D6
D5
D4
D3
D2
D1
D0
READ
PRI_LOS SEC_LOS HOLDOVER
UNLOCK
NU
DRVCLKA1
NU
DRVCLKA0
WRITE
NU NU NU NU NU
DRVCLKA1
NU
DRVCLKA0
0xA0A
Reset
X X X X X 0 X 0
PRI_LOS
Loss of primary reference clock detected.
This bit is high when the primary clock at the input of the PLL (i.e. after PLD mux) is loss.
SEC_LOS
Loss of secondary reference clock detected.
This bit is high when the primary clock at the input of the PLL (i.e. after PLD mux) is loss.
HOLDOVER
Hold over detected by the PLL.
UNLOCK
Unlock detected by the PLL.
DRVCLKA1
Drive transmission clock CLKA for AMC-B2
This bit is forced to 0 when AMC-B2 is absent or unpowered.
DRVCLKA0
Drive transmission clock CLKA for AMC-B1
This bit is forced to 0 when AMC-B2 is absent or unpowered.