![Kontron AdvancedTCA AT8001 Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/kontron/advancedtca-at8001/advancedtca-at8001_user-manual_1996242113.webp)
B-1
AT8001 User’s Guide
B.13
0A0CH: TELCLOCK4 (TELECOM CLOCK OPTION)
Address
Action
D7
D6
D5
D4
D3
D2
D1
D0
READ
NU NU NU NU NU
IRQTST RESET TEST
WRITE
NU NU NU NU NU
IRQTST RESET TEST
0xA0C
Reset
X X X X X
0 1 0
IRQTST
Interrupt test. The state of this bit is ored with the real interrupt. This bit is for software testing.
Ignore in normal operation. A "1" assert the interrupt request.
TEST
Ignore IPMC & shelf manager authorization.
Use this bit for testing only. In normal operation, leave this bit to 0 otherwise the AT8001 will not
be compliant with the ATCA specification.
RESET Hardware
reset of the PLL.
B.14
0A0DH: TELCLOCK5 (TELECOM CLOCK OPTION)
Address
Action
D7
D6
D5
D4
D3
D2
D1
D0
READ PCB
Version
WRITE
NU NU
0xA0D
Reset PCB
Version
PCB
Set to 1. Indicate that the compilation switch was properly set in the source code and that the PLD
is compiled for PCB revision 1. Prior "non-test" version of this PLD had this bit cleared. Should be
"1" for production boards.
VERSION
PLD code version.
Note that a value of:
PCB&Version = FF: indicate a test PLD to make a clock generator
PCB&Version = FE: indicate a test PLD used during manufacturing tests
Содержание AdvancedTCA AT8001
Страница 1: ...AT8001 User s Guide AdvancedTCA Document Revision 1 0 Ref M5002_TECH_1 July 2005 ...
Страница 28: ...2 10 AT8001 User s Guide 2 1 Block Diagram ...
Страница 59: ...3 2 AT8001 User s Guide 3 1 2 Setting Jumper locations ...
Страница 67: ...4 0 AT8001 User s Guide 4 Building an ATCA System Contents 4 1 Building an ATCA System 4 1 ...