![Kontron AdvancedTCA AT8001 Скачать руководство пользователя страница 109](http://html.mh-extra.com/html/kontron/advancedtca-at8001/advancedtca-at8001_user-manual_1996242109.webp)
B-4
AT8001 User’s Guide
B.8
0A04H: DEVELOPMENT FEATURES
Address
Action
D7
D6
D5
D4
D3
D2
D1
D0
READ MinorVersion
NU
PCB SSC1 SSC0
WRITE
NU NU NU NU NU NU
SSC1 SSC0
0xA04
Reset MinorVersion
X
PCB
1 1
MinorVersion
Minor version that doesn't impact the IPMC. For in-house minor version tracking.
SSC0
Special Serial Connection bit 0
SSC1
Special Serial Connection bit 1
PCB
PCB Version. Should be "1" for production stable boards.
Those bits define special connections between serial devices that are meaningless to the end user.
They are development and/or manufacturing facilities. Leave those bits in their default state for
end-user operation.
SSC[1:0]
Effect
11
Normal operation (no development tricks).
01
Float FW_RXD pin. Use this to program the FWUM with the POD.
10
Connect FW_RXD and FW_TXD to RJ45 RS232 port
00
Connect B1 (IPMC uart 1) to ICH UART1