1.2 Specification 
 

Main unit 

PARAMETER 

GSM frequency 

900/1800MHz, 850/1900MHz (optional) 

Alarm response time 

Less than 10s (GSM in normality)   

Standby power consumption 

1.5W 

Delay arm time 

30s 

Recording voice time 

9s 

External Power 

AC110-220V 50Hz or 60Hz; DC9V 

Backup battery (Li) 

DC7.4V, 700MAH 

Operating temperature 

-20

 ~ 60

 

Humidity 

95% 

Accessories 

PARAMETER 

Wireless frequency 

315±0.2Mhz/433±0.2Mhz 

Coding type 

Learning code 

Power requirements 

Remote controller: DC12V battery 

Indoor wired siren: DC12V battery 

Door/window magnetic contact: DC12V battery 

PIR sensor: 3V (two 1.5v batteries inside) 

Smoke detector: DC9V battery 

Gas detector: DC9V battery 

Shock sensor: DC12V battery 

Emergency button: DC12V battery 

Fence detector: DC12V, 110V to 220V 

Beam detector: DC12V, 110V to 220V 

Lifespan of battery 

half year (trigger 20 times everyday) 

Lower voltage reminder numerical value 

Door/window magnetic contact: 

10.5V 

PIR sensor: 

2.2V 

Shock sensor: 

3.3V 

 

 

 

 

 

 

 

 

Содержание KL-H50

Страница 1: ...U1 building Oriental Garden NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 1 KL H50 GSM HOME A...

Страница 2: ...rs for call alarm 3 2 4 Set delete check 1 SMS forwarding phone number 3 2 5 Recording voice 3 2 6 Change passwords 3 2 7 Change ID 3 2 8 Set date time 3 2 9 Set cancel fixed time arm disarm 3 3 Learn...

Страница 3: ...The function in details as follows 1 1 Function Feature Color LCD screen keypad with blue background light Maximum 4 wireless panic buttons 4 wireless fire detectors 16 remote controllers 32 wireless...

Страница 4: ...Hz DC9V Backup battery Li DC7 4V 700MAH Operating temperature 20 60 Humidity 95 Accessories PARAMETER Wireless frequency 315 0 2Mhz 433 0 2Mhz Coding type Learning code Power requirements Remote contr...

Страница 5: ...QTY IMAGE Remark Main unit 1pcs Remote controller 2pcs Arm disarm main unit Indoor wired siren 1pcs Wireless door window contact 1pcs With low voltage reminder function Wireless PIR sensor 1pcs With l...

Страница 6: ...den NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 6 1 4Main unit layout Note The background b...

Страница 7: ...ow contact sensor The door window magnetic contact includes two parts The sensor will send the wireless signal to the main unit immediately when the two parts depart more than 15 30mm 2 2 2 Install PI...

Страница 8: ...than air installation height from floor 0 3m 1 0m semi diameter to gas sources 1 5m detecting the gas lighter than air installation height from ceiling 0 3m 1 0m semi diameter to gas sources 1 5m 2 2...

Страница 9: ...one numbers for SMS alarm a Set the mobile phone number After passing the verification of administrator password press SET button when SET SMS appears on the LCD display input N mobile phone number OK...

Страница 10: ...on of administrator password press SET button to move cursor when SET REC appear on the LCD display press OK to begin the 9 seconds record The main unit LCD starts to count down and exits automaticall...

Страница 11: ...rn cancel remote controller a Learn remote control After passing the verification of administrator password press SET button to move cursor when SET COM appears on the LCD display input 1 N OK the LCD...

Страница 12: ...OK on Main unit keyboard the LCD will stop to flash in 4s All of them are deleted 3 4 Exit setting In the setting mode press ESC to exit The setting mode will exit automatically if no response within...

Страница 13: ...numbers for SMS alarm a Set the mobile phone number SMS format four digits of administrator password DS N mobile phone number Note N stands for 1 2 3 4 5 Example Set 1388888888 as the first SMS receiv...

Страница 14: ...8 as the new password Send SMS 1234DP5678 5 5 Arm disarm Arm by SMS 4 digits of administrator password A1 Disarm by SMS 4 digits of administrator password A2 Example The Main unit s administrator pass...

Страница 15: ...5s Note Zone 1 and zone 2 can be set as delay alarm zones Suggest users to install the delay alarm zone sensors on the way from door to alarm main unit User will have enough time to disarm the alarm s...

Страница 16: ...and the LCD show LO zone number to remind of users change battery 6 5 Deal with alarm SMS TEL and zones appear on the LCD display in alarm mode P external power failure E Emergency alarm F fire alarm...

Страница 17: ...unication If the user hand up the phone the host will automatically terminate the operation 7 Events record History record a After passing the verification of administrator password press SET button t...

Страница 18: ...disarm by 8th remote controller A8 disarm by 9th remote controller A9 disarm by 10th remote controller AA disarm by 11th remote controller AB disarm by 12th remote controller AC disarm by 13th remote...

Страница 19: ...02 alarm 27 emergency zone 03 alarm 28 emergency zone 04 alarm 29 wired door window zone 01 alarm 2A wired door window zone 02 alarm 2B wired zone 03 alarm 2C wired zone 04 alarm 2D wired zone 05 ala...