KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail:
MSN:
Skype: securitykonlen
- 10 -
The messages from the pre-set phone number can be forwarded to the first alarm SMS receiving
phone number. Recommend users to set the mobile company phone number so that users can know
the SIM card status of main unit timely to make sure normal communication.
a) After passing the verification of administrator password, press “SET” button, when “SET, SMS” appears on
the LCD display.
Input: N
﹢
phone OK
Note: N stands for 6
Example: The mobile company phone number is 10086,
The preset first alarm SMS receiving phone number. is 1368888888
Input: 6 + 10086 + OK, then two sounds of “di, di” for confirmation.
When the mobile company sends a SMS of “Your mobile no enough money, please charge soon”, the
message will be forwarded to 1368888888 automatically.
Note: The phone number can be deleted and checked as per the point b) & c) of 3.2.2/ 3.2.3
3.2.5 Record voice
After passing the verification of administrator password, press ”SET” button to move cursor, when “SET, REC”
appear on the LCD display, press “OK” to begin the 9 seconds record. The main unit LCD starts to count down
and exits automatically in 9 second. Press “CHECK” to play the record.
3.2.6 Change password
After passing the verification of administrator password, press “SET” button to move cursor, when “SET, PAS”
appears on the LCD display, operate as below
Example: Set 4321 as the new administrator password.
Input: 1 + 4321 + “OK”, then you will hear “di, di” sound for confirmation.
3.2.7 Change ID
After passing the verification of administrator password, press “SET” button to move cursor, when “SET, ID”
appears on the LCD display, input: six new ID n OK,
Note: the initial ID is 000000.
Example: Set 123456 as the new ID.
Input: “OK”, then two sounds of “di, di” for confirmation.
Press “check” to inquiry the new ID
3.2.8 Set data & time
After passing the verification of administrator, press “SET” to move cursor, when “SET,
” appears on the
LCD display,
Input: * + year/month/day/hour/minute/second (each with two numbers) + OK, then you will hear “di, di” sound
Level
Type
Factory password
Changing command
Check new
password
1
Administrator
Password
1234
1 + new pa
OK
1+ check
2
Disarm Password
5678
2 + new pa
OK
2 + check
3
Inquiry Password
9012
3 + new pa
OK
3 + check