Note: A stand for independent arm zone 

            Zone01 to 24 can be programmed as independent arm/disarm zones which only SMS can arm/disarm 

them, no use by remote controller). 

b) Inquiry independent arm zone 

By the main unit keypad: After passing the verification of administrator password, press “SET” button to move 

cursor, when “SET, TYPE” appears on the LCD screen, press "check". Then main unit send a SMS like above 

example to the preset five SMS receiving phone numbers. 

By SMS: Send a SMS order like this: Administrator pa AA to main unit, then main unit reply a SMS 

about the independent arm/disarm zone information to preset five SMS receiving phone numbers 

c) Independent disarm 

Send SMS: Administrator pa AD + zone (01, 02...24) to disarm the preset independent arm zones. 

 

5.8 Delay alarm setting 

SMS format: 1234 + zone number ( 1 or 2) + D + delay alarm time (00s, 15s, 30s or 45s) 

Note: Zone 1 and zone 2 can be set as delay alarm zones.   

Suggest users to install the delay alarm zone sensors on the way from door to alarm main unit. 

User will have enough time to disarm the alarm system while entering into the house. 

Example: Set zone 1 and zone 2 as delay alarm zones, and the delay alarm time is 30s. 

Send SMS: 12341D30 and 12342D30 to alarm main unit by two separate SMS. 

The alarm system will make “ DI, DI, DI….” sound to remind user to disarm it soon whe n entering into the 

house. The system will make alarm immediately in 30s if the system is still not be disarmed. 

 

5.9 Inquire arm/disarm status 

Send SMS: 4 digits of administrator pa W1 

Reply SMS: The Main unit’s arm/disarm status   

5.10 Inquire external power status 

Send SMS: 4 digits of administrator pa W2 

Reply SMS: The Main unit’s external power status 

6. Usage 

6.1 Remote controller 

                                                                           

 

       

 

 

 

 

 

 

a)  Delayed  Arm:  Press  

”  on  remote  controller  or  main  unit,  the  main  unit  is  counting  down  with  “di,di…” 

sound and red “

” icon on LCD is flashing. 25 second later, two long “di, di” sound confirm the system enter 

into arm status and the “

” icon stops to flash. 

b) Quick arm: Press 

” on remote controller and then press “

” immediately, the system is armed quickly.   

c)  Emergency  alarm:  Learning  code  the  “

”  as  panic  button  first,  press  “

”,  the  main  unit  auto-dial  the 

Содержание KL-H50

Страница 1: ...U1 building Oriental Garden NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 1 KL H50 GSM HOME A...

Страница 2: ...rs for call alarm 3 2 4 Set delete check 1 SMS forwarding phone number 3 2 5 Recording voice 3 2 6 Change passwords 3 2 7 Change ID 3 2 8 Set date time 3 2 9 Set cancel fixed time arm disarm 3 3 Learn...

Страница 3: ...The function in details as follows 1 1 Function Feature Color LCD screen keypad with blue background light Maximum 4 wireless panic buttons 4 wireless fire detectors 16 remote controllers 32 wireless...

Страница 4: ...Hz DC9V Backup battery Li DC7 4V 700MAH Operating temperature 20 60 Humidity 95 Accessories PARAMETER Wireless frequency 315 0 2Mhz 433 0 2Mhz Coding type Learning code Power requirements Remote contr...

Страница 5: ...QTY IMAGE Remark Main unit 1pcs Remote controller 2pcs Arm disarm main unit Indoor wired siren 1pcs Wireless door window contact 1pcs With low voltage reminder function Wireless PIR sensor 1pcs With l...

Страница 6: ...den NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 6 1 4Main unit layout Note The background b...

Страница 7: ...ow contact sensor The door window magnetic contact includes two parts The sensor will send the wireless signal to the main unit immediately when the two parts depart more than 15 30mm 2 2 2 Install PI...

Страница 8: ...than air installation height from floor 0 3m 1 0m semi diameter to gas sources 1 5m detecting the gas lighter than air installation height from ceiling 0 3m 1 0m semi diameter to gas sources 1 5m 2 2...

Страница 9: ...one numbers for SMS alarm a Set the mobile phone number After passing the verification of administrator password press SET button when SET SMS appears on the LCD display input N mobile phone number OK...

Страница 10: ...on of administrator password press SET button to move cursor when SET REC appear on the LCD display press OK to begin the 9 seconds record The main unit LCD starts to count down and exits automaticall...

Страница 11: ...rn cancel remote controller a Learn remote control After passing the verification of administrator password press SET button to move cursor when SET COM appears on the LCD display input 1 N OK the LCD...

Страница 12: ...OK on Main unit keyboard the LCD will stop to flash in 4s All of them are deleted 3 4 Exit setting In the setting mode press ESC to exit The setting mode will exit automatically if no response within...

Страница 13: ...numbers for SMS alarm a Set the mobile phone number SMS format four digits of administrator password DS N mobile phone number Note N stands for 1 2 3 4 5 Example Set 1388888888 as the first SMS receiv...

Страница 14: ...8 as the new password Send SMS 1234DP5678 5 5 Arm disarm Arm by SMS 4 digits of administrator password A1 Disarm by SMS 4 digits of administrator password A2 Example The Main unit s administrator pass...

Страница 15: ...5s Note Zone 1 and zone 2 can be set as delay alarm zones Suggest users to install the delay alarm zone sensors on the way from door to alarm main unit User will have enough time to disarm the alarm s...

Страница 16: ...and the LCD show LO zone number to remind of users change battery 6 5 Deal with alarm SMS TEL and zones appear on the LCD display in alarm mode P external power failure E Emergency alarm F fire alarm...

Страница 17: ...unication If the user hand up the phone the host will automatically terminate the operation 7 Events record History record a After passing the verification of administrator password press SET button t...

Страница 18: ...disarm by 8th remote controller A8 disarm by 9th remote controller A9 disarm by 10th remote controller AA disarm by 11th remote controller AB disarm by 12th remote controller AC disarm by 13th remote...

Страница 19: ...02 alarm 27 emergency zone 03 alarm 28 emergency zone 04 alarm 29 wired door window zone 01 alarm 2A wired door window zone 02 alarm 2B wired zone 03 alarm 2C wired zone 04 alarm 2D wired zone 05 ala...

Отзывы: