Zone 33 to 36 for wireless fire alarm detectors, such as wireless smoke/gas detectors 

Zone 37 to 40 for wireless emergency button 

Example: learn first wireless PIR sensors, press 201OK on keyboard of main unit. 

                  Learn first wireless smoke detectors, press 233OK 

                  Learn the second wireless emergency button, press 238OK. 

 

b) Cancel wireless sensors. 

After passing the  verification of administrator password, press “SET” button,  when “SET, COM” appears on 

the LCD display, input # + N + OK, the LCD will flash three seconds, then stop. The wireless sensor is deleted 

successfully. Note: N stand for 01, 02, 03, 04………40. 

 

3.3.3 Cancel all the wireless accessories. 

After passing the  verification of administrator password, press “SET” button,  when “SET, COM” appears on 

the  LCD  display,  input  999  +OK  on  Main  unit  keyboard,  the  LCD  will  stop  to  flash  in  4s.  All  of  them  are 

deleted. 

3.4 Exit setting   

In  the  setting  mode,  press  “ESC”  to  exit.  The  setting  mode  will  exit  automatically  if  no  response  within  15 
seconds. 
 

4. Zone classification 

Total 40 wireless zones, each zone can only learn one wireless sensor. 

01-28: common zones 

01-24: can be programmed as independent arm/disarm zone 

29-30: special zones 

*Only fifteenth remote controller can arm/disarm it,   

* Only send alert to the preset forth alarm receiving phone number. 

* The fifteenth remote controller can control 01 to 28 and 29, 30. 

31-32: special zone 

  *only sixteenth remote controller can arm/disarm it. 

  *only send alert to the preset fifth alarm receiving phone number. 

  *The sixteenth remote controller can control 01 to 28 and 31, 32 

33-36: 24 hours (full day arm) fire alarm zone for wireless gas/smoke detectors. 

37-40: 24 hours (full day arm) emergency zone for wireless panic button. 

 

Example:   

CEO    room 

Zone 29 

GM Room 

Zone32 

 

Financial dept 

Zone 01 

 

 

Personnel    dept 

Zone 02 

 

Marketing Dept 

Zone 03 

Customer service 

Dept zone 04 

 

R & D dept zone 05 

Engineering dept zone 

06 

Shipping dept 

  zone 07 

Purchasing dept   

zone 08 

Ware house 

09 

Production dept 

10 

 

Содержание KL-H50

Страница 1: ...U1 building Oriental Garden NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 1 KL H50 GSM HOME A...

Страница 2: ...rs for call alarm 3 2 4 Set delete check 1 SMS forwarding phone number 3 2 5 Recording voice 3 2 6 Change passwords 3 2 7 Change ID 3 2 8 Set date time 3 2 9 Set cancel fixed time arm disarm 3 3 Learn...

Страница 3: ...The function in details as follows 1 1 Function Feature Color LCD screen keypad with blue background light Maximum 4 wireless panic buttons 4 wireless fire detectors 16 remote controllers 32 wireless...

Страница 4: ...Hz DC9V Backup battery Li DC7 4V 700MAH Operating temperature 20 60 Humidity 95 Accessories PARAMETER Wireless frequency 315 0 2Mhz 433 0 2Mhz Coding type Learning code Power requirements Remote contr...

Страница 5: ...QTY IMAGE Remark Main unit 1pcs Remote controller 2pcs Arm disarm main unit Indoor wired siren 1pcs Wireless door window contact 1pcs With low voltage reminder function Wireless PIR sensor 1pcs With l...

Страница 6: ...den NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 6 1 4Main unit layout Note The background b...

Страница 7: ...ow contact sensor The door window magnetic contact includes two parts The sensor will send the wireless signal to the main unit immediately when the two parts depart more than 15 30mm 2 2 2 Install PI...

Страница 8: ...than air installation height from floor 0 3m 1 0m semi diameter to gas sources 1 5m detecting the gas lighter than air installation height from ceiling 0 3m 1 0m semi diameter to gas sources 1 5m 2 2...

Страница 9: ...one numbers for SMS alarm a Set the mobile phone number After passing the verification of administrator password press SET button when SET SMS appears on the LCD display input N mobile phone number OK...

Страница 10: ...on of administrator password press SET button to move cursor when SET REC appear on the LCD display press OK to begin the 9 seconds record The main unit LCD starts to count down and exits automaticall...

Страница 11: ...rn cancel remote controller a Learn remote control After passing the verification of administrator password press SET button to move cursor when SET COM appears on the LCD display input 1 N OK the LCD...

Страница 12: ...OK on Main unit keyboard the LCD will stop to flash in 4s All of them are deleted 3 4 Exit setting In the setting mode press ESC to exit The setting mode will exit automatically if no response within...

Страница 13: ...numbers for SMS alarm a Set the mobile phone number SMS format four digits of administrator password DS N mobile phone number Note N stands for 1 2 3 4 5 Example Set 1388888888 as the first SMS receiv...

Страница 14: ...8 as the new password Send SMS 1234DP5678 5 5 Arm disarm Arm by SMS 4 digits of administrator password A1 Disarm by SMS 4 digits of administrator password A2 Example The Main unit s administrator pass...

Страница 15: ...5s Note Zone 1 and zone 2 can be set as delay alarm zones Suggest users to install the delay alarm zone sensors on the way from door to alarm main unit User will have enough time to disarm the alarm s...

Страница 16: ...and the LCD show LO zone number to remind of users change battery 6 5 Deal with alarm SMS TEL and zones appear on the LCD display in alarm mode P external power failure E Emergency alarm F fire alarm...

Страница 17: ...unication If the user hand up the phone the host will automatically terminate the operation 7 Events record History record a After passing the verification of administrator password press SET button t...

Страница 18: ...disarm by 8th remote controller A8 disarm by 9th remote controller A9 disarm by 10th remote controller AA disarm by 11th remote controller AB disarm by 12th remote controller AC disarm by 13th remote...

Страница 19: ...02 alarm 27 emergency zone 03 alarm 28 emergency zone 04 alarm 29 wired door window zone 01 alarm 2A wired door window zone 02 alarm 2B wired zone 03 alarm 2C wired zone 04 alarm 2D wired zone 05 ala...

Отзывы: