20
To move the cursor on the screen, use “UP” and “DOWN” key on the DVR front panel or remote
control and then press “SELECT” button to change the numeric value. Once you finish time
setting, press “MENU” button. Then press “DOWN” key and “SELECT” button to apply the new
time set. Or move the mouse to move the cursor up and down, hold a left mouse click button to
change the numeric value. Once you finish time setting, hold a right mouse click button to return.
Then move the mouse to the order of “Apply” to left click to apply the new time set.
EVENT LIST
EVENT LIST function enables playback by
event. On the Event List menu, it shows all
past recorded video, start time and end time
of each recorded video, and etc showing
recording year/date/time in list. The HDD
can be stored 300 pieces of event in it at
most. If the events are over 300 pieces, user
can play previous event according to input
time period if the data hasn’t been over-
written.
To playback by EVEN LIST, using [UP]/[DOWN] or channel number (CH3 for Page Up or CH4 for
Page Down) key on the front panel or remote control, select the event that you want to playback
and press “PLAY” button. Another way, move the mouse up and down or click the left mouse
button (“
◄ for Page Up or ► for Page Down), select the event that you want to playback and
double click the left mouse button. Then it wills playback the recording video data.
PTZ SETUP
Adjust the RS485 setting depending on the
PTZ camera that you have.
Our DVR system supports PELCO-D
protocol and PELCO-P protocol. Then we
can see the diagram that is on the left. For
example, we select the channel 1 to set up.
Dome’s address is 1. Protocol makes use of
PELCO-D. Baud rate is 2400 and Dome’s
speed is 7.
CHANEL:
Select a camera channel where PTZ camera is connected.
ADDRESS:
Dome’s address “
0-255
” (
PELCO-D
) and “
0-31
” (
PELCO-P
).
PROTOCOL:
Including “
PELCO-D
”, “
PELCO-P
”. Set the protocol according to the dome’s
protocol.
BAUD RATE:
Press “
SEL
” button to select the value
1200
,
2400
,
4800
,
9600
,
19200
bps.
SPEED:
Having “
1-10
” to select.
PRESET:
If protocol is
PELCO-D
, preset includes “
1-32
”. If protocol is
PELCO-P
, preset includes
“
1-255
”. When it displays
0
, it suggests that the place’s preset is not using.