![Konica Minolta PB-501 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/konica-minolta/pb-501/pb-501_installation-manual_1994004006.webp)
E-6
5. Remove the top cover of the book receptacle (2
screws).
Note:
A connector is on the rear side of the top cover.
Make sure not to forcibly disconnect the connector
when opening the top cover.
6. Turn OFF the DIP SW1.
Note:
• This procedure is required because by default it
is set for a C6500/C6501 series. (Factory
default of SW1: ON)
• Do not change other switches.
7. Remove the CN-29 connector from the control
board.
8. Remove the short connector from the clamp.
9. Connect the short connector to the CN-29, and
secure the connector 29 with the clamp.
10. Install the top cover on the book receptacle (2
screws).
11. Perform a software update (ISW).
For ISW procedures, see the service manual.
Note:
The software is designed for the C6500/C6501
series, so be sure to run it.
Note:
Perform the operations described in "V.Common
operations after installing PB-501", page 17 to 19.
A075IXE023SA
Top cover of the book receptacle
A connector is
on the rear side.
A075IXE042CA
A075IXE025SB
CN-29
Short connector
Clamp
A075IXE024SB
CN-29
Short connector
Connector 29