![Konica Minolta PB-501 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/konica-minolta/pb-501/pb-501_installation-manual_1994004003.webp)
E-3
III. Preparation Prior to Installation
1. Visually inspect the unit.
2. Remove the locking tapes and locking materials.
3. Remove the accessory parts.
Note:
One more locking tape is on the rear side of the
book receptacle.
4. Open the front door of the PB-501, and remove six
locking materials (24 screws), the locking tapes
and the cushion.
Note:
There is a plastic sheet under the cushion, so be
sure to remove it.
5. Pull out the clamp unit and remove the locking tapes.
(8 places)
6. Push back the glue injector.
Note:
Push the upper right part of the glue injector (cir-
clemarked part).
7. Using the screw holes in the place the lower-right
locking material was removed, install the pro-
cessing cover/1 with two screws. (TP screw
M4x6: 2 pcs.)
8. Remove the two locking tapes and the protection
paper.
A075IXE001SA
Locking tapes
Guide tape
Accessory
parts
Locking tapes
Locking tapes
Locking materials
A075IXE003SA
Locking tapes
Locking materials
Right lower
Locking
materials
Cushion
A075IXE004SA
Locking tape
Clamp unit
Locking tapes
Locking
tapes
A075IXE005SA
Glue injector
Processing cover/1
TP screws M4x6
A075IXE006SA
Locking tapes
Protection paper