E-12
5. Remove the top cover of the book receptacle (2
screws).
(For the 1050 series only)
Note:
A connector is on the rear side of the top cover.
Make sure not to forcibly disconnect the connector
when opening the top cover.
6. Turn OFF the DIP SW1.
(For the 1050 series only)
Note:
• This procedure is required because by default it
is set for a C6500/C6501 series. (Factory
default of SW1: ON)
• Do not change other switches.
7. Install the top cover on the book receptacle (2
screws).
8. Perform a software update (ISW).
For ISW procedures, see the service manual.
(For the 1050 series only)
Note:
The software is designed for the C6500/C6501
series, so be sure to run it.
Note:
Perform the operations described in "V.Common
operations after installing PB-501", page 17 to 19.
1. Turn the machine’s Sub and Main power switches
OFF, and unplug the power cord.
2. Install the Installation plate 1, the Installation plate
2, the Installation plate 3, and the Installation plate
5 on the left side of the LS-501 (LS-505) as below.
(TP screw M4x6: 8 pcs.)
3. Remove the connector cover on the left side of
the LS-501 (LS-505) (1 screw).
A075IXE023SA
Top cover of the book receptacle
A connector is
on the rear side.
A075IXE042CA
Installation procedure for
[PB-501 + LS-501 (LS-505) + 1050 series]
[PB-501 + LS-501 (LS-505) + RU-503 (RU-504)
+ C6500/C6501 series]
* For the installation procedure for the RU-503,
see the RU-503/504 installation manual.
(C6501 series is only for the RU-504.)
A075IXE026SA
Installation
plate 1
TP screws M4x6
Installation
plate 2
TP screws M4x6
Installation
plate 5
TP screws M4x6
Installation
plate 3
TP screws M4x6
Put screws in the
holes on the right.
Connector cover