E-10
(2) Align the bottom holes of the front cover with
the pins of the power supply unit, and use the
temporarily placed screws to secure it.
Note:
If the front cover does not close because it touches
the machine or optional unit, adjust the horizontal
position or angle of the front cover. If the actuator
does not turn the interlock switch ON, adjust the
position of the actuator adjustment plate as well.
Note:
Perform the operations described in "V.Common
operations after installing PB-501", page 17 to 19.
1. Turn the machine’s Sub and Main power switches
OFF, and unplug the power cord.
2. Install the Installation plate 1, the Installation plate
2, the Installation plate 3, and the Installation plate
5 on the left side of the SD-501 (SD-506) as below.
(TP screw M4x6: 8 pcs.)
3. Remove the connector cover on the left side of
the SD-501 (SD-506) (1 screw).
15AQIXE061SA
Pin
Pin
Loosen the
screws to
adjust the
horizontal
position
Actuator adjustment plate
Loosen the screw to adjust the angle
Loosen the screw to
adjust the horizontal position
15AQIXF062SA
Installation procedure for
[PB-501 + SD-501 (SD-506) + 1050 series]
[PB-501 + SD-501 (SD-506) + RU-503 (RU-504)
+ C6500/C6501 series]
* For the installation procedure for the RU-503,
see the RU-503/504 installation manual.
(C6501 series is only for the RU-504.)
A075IXE019SA
Installation
plate 1
TP screws M4x6
Installation
plate 2
TP screws M4x6
Installation
plate 5
TP screws M4x6
Installation
plate 3
TP screws M4x6
Put screws in the
holes on the right.
Connector cover
15AEIXE033SA