Field Service Ver. 1.0 Jun. 2008
2. Periodical check
DF-612/SP-503/MS-501
Maintenance
2.1.3
Regist rollers/exit rollers
A. Periodically cleaning parts/cycle
• Regist rollers: Every 30,000 originals feed
• Exit rollers: Every 30,000 originals feed
B. Cleaning procedure
1.
Open the feed cover [1].
2.
Using a cleaning pad dampened with
alcohol, wipe three regist rollers [1]
and three rolls [2] clean of dirt.
3.
Lift up the document feed tray.
4.
Using a cleaning pad dampened with
alcohol, wipe two exit rollers [1] and
two rolls [2] clean of dirt.
A0EYF2C500DA
[1]
A0EYF2C042DA
[1]
[2]
A0EYF2C043DA
[1]