![Kongsberg Simrad Mk3 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/kongsberg/simrad-mk3/simrad-mk3_installation-manual_1992574032.webp)
32
110-0001063/A
Context
The Processor Unit offers several USB interface sockets. The USB sockets can be used
to interface peripheral devices such as USB flash drives, portable hard disks, mouse
and keyboard.
Dedicated USB ports are provided for the "Wake-up on USB" functionality. "Wake-up
on USB" means that you can turn on the sonar system by activating any USB device
connected to a compatible USB port.
The sockets supporting "Wake-up on USB" are identified on the connector label.
Tip
If you choose to enable the "Wake-up on USB" functionality, it may not be appropriate
for the entire sonar system to start up when you accidentally touch the operating panel.
You can prevent the sonar program from starting when the Processor Unit is turned on.
To start the program - and turn on the entire sonar system - you must then double-click
the sonar icon on the Processor Unit desktop.
Procedure
1
Restart the Processor Unit.
2
During the boot sequence, when prompted, press
DEL
to run the setup program.
Observe that the program starts.
Use the arrow keys on the keyboard to move the cursor.
Press
Escape
on the keyboard to go one step "back". In some situations,
Escape
will
attempt to close the BIOS setup program.
3
Select
Advanced
on the
Main
menu.
4
Select
USB Configuration
.
5
Set
USB S5 Wake-up support
to
Enabled
.
6
Press
Escape
to return to the
Main
menu.
7
Save the chosen parameters, and exit.
a
Select
Save & Exit
on the
Main
menu.
b
Select
Save Changes and Exit
.
c
When asked if you wish to save the configuration and exit, select
Yes
.
d
Allow the Processor Unit to restart.