The maximum length of the Ethernet cable is 100 meters.

Serial line connectors

Maximum length for an RS-232 serial cable is typically 60 meters with 2400 bps data
rate, however this depends on the cable quality. Always check the cable manufacturers
specifications for the actual "shunt capacitance". A common figure is 47.5 pF/m, which
gives a maximum cable length of about 50 meters.

Even though a standard exist for RS-232 pin configuration, certain manufacturer may
still choose their own connector pins for the various signals used. In order to make the
RS-232 connection to your peripheral device work properly, you must always consult the
relevant instructions provided by the device manufacturer.

Note

Observe that long runs of unshielded cable will pick up noise easily. This is because
the RS-232 signals are not balanced.

COM1/COM2/COM3/COM4

This serial port is set up for RS422 communication. In order to set up the serial
ports to match your interface requirements, use the dedicated software utility in the
device driver. If you need to change these settings, contact your local dealer or
distributor for advice. You can also contact our support department.

COM5

This serial port is set up for RS232 communication. This serial communication
format is fixed and cannot be changed. This serial port may not be fitted on all
computer models.

Use USB-to-serial converters if additional serial lines are required. Several types are
commercially available. Note that most USB-to-serial converters will introduce some
latency. They may also introduce jitter in the communication. The amount of jitter
depends on the quality of the converter.

USB connectors

The Processor Unit offers several USB interface sockets. The USB sockets can be used
to interface peripheral devices such as USB flash drives, portable hard disks, mouse and
keyboard. USB is normally not used to interface peripheral devices, but this may be
possible if you use USB to Serial converters. Note that most USB-to-serial converters
will introduce some latency. They may also introduce jitter in the communication. The
amount of jitter depends on the quality of the converter.

Dedicated USB ports are provided for the "Wake-up on USB" functionality. "Wake-up
on USB" means that you can turn on the sonar system by activating any USB device
connected to a compatible USB port. The computer BIOS (Basic Input/Output System)
must be modified to support this functionality.

The sockets supporting "Wake-up on USB" are identified on the connector label.

Simrad Installation Manual

Содержание Simrad Mk3

Страница 1: ...publication is intended for technical personnel such as skilled shipyard workers electricians qualified engineers and naval architects Additional end user documents related to the sonar system can be...

Страница 2: ...er use or maintenance may cause damage to the equipment and or injury to personnel You must be familiar with the contents of the appropriate manuals before attempting to operate or work on the equipme...

Страница 3: ...nel description Nexcom NISE 3900E 22 Processor Unit rear panel description Nexcom NISE 3900E 23 SETTING TO WORK 26 Visual inspection of the Operating Panel 26 Selecting which Operating Panel to use 27...

Страница 4: ...4 110 0001063 A Simrad...

Страница 5: ...s well as the relevant work standards and mounting procedures If required all documents provided by the shipyard for the physical installation of the sonar system must be approved by the vessel s nati...

Страница 6: ...trademark of Microsoft Corporation in the United States and other countries Simrad SIMRAD and the Simrad logo are either registered trademarks or trademarks of Kongsberg Maritime AS in Norway and oth...

Страница 7: ...o key functionality All the functionality provided by the sonar system can be accessed using the trackball on the Operating Panel and the menu system shown in the display presentation The sonar system...

Страница 8: ...of our support offices A list of all our offices and dealers is available on our website You can also contact our main support office in Norway Norway main office Company name Kongsberg Maritime AS Si...

Страница 9: ...604 464 8144 Telefax 1 604 941 5423 Website www kongsberg com simrad Email address simrad canada simrad com Malaysia Company name Kongsberg Maritime Malaysia Sdn Bhd Address Unit 27 5 Signature Office...

Страница 10: ...Maritime China Ltd Address 555 Chuanqiao Road China Shanghai Pilot Free Trade Zone 201206 China Telephone 86 21 3127 9888 Telefax 86 21 3127 9555 Website www kongsberg com simrad Email address simrad...

Страница 11: ...fferent screwdriver types pliers spanners a cable stripper a soldering iron etc Each tool must be provided in various sizes We recommend that all tools are demagnetized to protect your equipment Depen...

Страница 12: ...allow future maintenance you must mount the unit with its cables and connectors available for easy access 2 Drill and cut the panel opening as shown in drawing 476352 3 Mount the Operating Panel usin...

Страница 13: ...110 0001063 A 13 476352 Operating Panel dimensions Mk3 Download the source drawing from our website kongsberg com fisherysonar Installation...

Страница 14: ...14 110 0001063 A Simrad Installation Manual...

Страница 15: ...110 0001063 A 15 Installation...

Страница 16: ...ing Panel and the Processor Unit page 17 Operating Panel connectors Mk3 page 18 Processor Unit rear panel description HT20470 DC Version page 19 Processor Unit front panel description Nexcom NISE 3900...

Страница 17: ...data cable One end of the USB cable is fitted with a quadratic USB connector B plug The other end is fitted with a rectangular USB connector A plug This cable is included in the delivery The cable le...

Страница 18: ...vailable socket on the Processor Unit Tip The HT20470 Processor Unit allows you to enable wake up on USB functionality Wake up on USB means that you can turn on the sonar system by activating any USB...

Страница 19: ...ors The purpose of each Ethernet connector is predefined LAN1 Spare Not used LAN2 Ship network Use this socket if you want to connect your sonar system to the ship s local area network LAN LAN3 Simrad...

Страница 20: ...partment COM5 This serial port is set up for RS232 communication This serial communication format is fixed and cannot be changed This serial port may not be fitted on all computer models Use USB to se...

Страница 21: ...110 0001063 A 21 On the illustration the sockets are identified with the following character M Related topics Cable layout and interconnections page 16 Cable layout and interconnections...

Страница 22: ...interface ports LED indicators and an on off switch A USB 2 0 ports B Graphics adapter DisplayPort C Audio input output D Serial port The number and physical location of the serial ports may differ f...

Страница 23: ...tors The purpose of each Ethernet connector is predefined ETH1 Simrad Connect Use this socket for Ethernet communication with other Simrad products The Mk2 Operating Panel must be connected to this Et...

Страница 24: ...meters Even though a standard exist for RS 232 pin configuration certain manufacturer may still choose their own connector pins for the various signals used In order to make the RS 232 connection to...

Страница 25: ...al types are commercially available Note that most USB to serial converters will introduce some latency They may also introduce jitter in the communication The amount of jitter depends on the quality...

Страница 26: ...em hardware units are installed as specified in this manual The sonar system is turned off You need the following equipment Multimeter Procedure 1 Make sure that the Operating Panel is installed in th...

Страница 27: ...been identified with the relevant product label s and that one label includes the part and serial numbers Result Requirements Results The Operating Panel is correctly installed with easy access for ma...

Страница 28: ...nstallation dialog box is located on the Setup menu Tip When you work in the Installation dialog box you must always select Apply to save the changes made on a page You must do this before you continu...

Страница 29: ...ns This dialog box contains a number of pages selected from the menu on the left side 3 On the left side of the Installation dialog box select Operating Panel 4 Select Operating Panel Mk3 5 Under Rota...

Страница 30: ...Tilt mode is started The chosen tilt sector is shown on the tilt indicator in the Horizontal view using a shaded background The sector and step settings are made using the Tilt function on the Main me...

Страница 31: ...r offers several different marker types You can add as many markers as you like The most common markers can be added using dedicated buttons on the Operating Panel Other markers are added using the sh...

Страница 32: ...rom starting when the Processor Unit is turned on To start the program and turn on the entire sonar system you must then double click the sonar icon on the Processor Unit desktop Procedure 1 Restart t...

Страница 33: ...You can prevent the sonar program from starting when the Processor Unit is turned on To start the program and turn on the entire sonar system you must then double click the sonar icon on the Processor...

Страница 34: ...chnical specifications page 35 Operating Panel power requirements Mk3 page 35 Operating Panel weight and outline dimensions Mk3 page 35 Operating Panel environmental requirements Mk3 page 36 Operating...

Страница 35: ...ity and performance of our products The technical specifications may be changed without prior notice Operating Panel power requirements Mk3 Make and model Sonar Operating Panel Mk3 Voltage requirement...

Страница 36: ...to 95 relative non condensing Ingress protection IP code IP65 Related topics Technical specifications page 34 Operating Panel compass safe distance Mk3 Make and model Sonar Operating Panel Mk3 Standa...

Страница 37: ......

Страница 38: ...2022 Kongsberg Maritime...

Отзывы: