451253/A
43
• Lifting device
• Rope
• Tackles
Context
Mounting frames are designed to house the individual transducer modules. While the
transducer modules are mounted into the frames, the frames require casings.
The installation must be carried out according to arrangement drawings designed for the
specific vessel. Refer to the drawings included in the Drawing File, and the applicable
drawings prepared by the installation shipyard.
Note
The mounting frames must be handled with care. Please observe normal safety
precautions for dockyard work and welding.
Procedure
1
Mount the CCU (Cable Connection Unit) to the frame before the frame is installed.
The CCU(s) should be mounted on the side of the mounting frame.
2
Mount the frame in the casings.
The mounting frames must be bolted onto the flat bars inside the casing. The
number of flat bars depends on the length of the transducer array. There are three
(3) holes in each flat bar.
The frames are fastened by M16 bolts. Bolts of grade A4-80 should be used.
Use a torque of 187 Nm.
3
Check that the each frame is mounted completely flat.
Important
No point on the frame may deviate from the ideal plane with more than 0.6 mm.
The maximum allowed gradient between two adjacent mounting points on the
frame is 0.1 % (1 mm/m).
This can be checked by measuring the relative vertical positions of the module
mounting bars on the frames. If the deviations are too large, this has to be corrected
by applying shims.
When the frame is installed completely flat:
4
Remove one bolt.
5
Apply Loctite 242 to the bolt.
6
Install the bolt using a torque of 187 Nm.
Содержание SBP 29
Страница 1: ...451253 A November 2019 Kongsberg Maritime AS SBP 29 Sub bottom profiler Installation Manual ...
Страница 57: ...451253 A 57 Cable plan overview Overview of the SBP 29 cable plan Cable layout and interconnections ...
Страница 111: ...451253 A 111 Figure 12 862 216859 Drawing files ...
Страница 112: ...112 451253 A Figure 13 307904 SBP 29 Installation Manual ...
Страница 113: ...451253 A 113 Figure 14 862 218001 Drawing files ...
Страница 114: ...114 451253 A Figure 15 871 219193 SBP 29 Installation Manual ...
Страница 115: ...451253 A 115 Figure 16 871 219201 Drawing files ...
Страница 116: ...116 451253 A Figure 17 388168 SBP 29 Installation Manual ...
Страница 117: ...451253 A 117 Figure 18 871 219187 Drawing files ...
Страница 118: ...118 451253 A Figure 19 821 219199 SBP 29 Installation Manual ...
Страница 119: ...451253 A 119 Figure 20 388235 Drawing files ...
Страница 120: ...120 451253 A Figure 21 871 219198 SBP 29 Installation Manual ...
Страница 121: ...451253 A 121 Figure 22 388148 Drawing files ...
Страница 122: ...122 451253 A Figure 23 315550 SBP 29 Installation Manual ...
Страница 123: ...451253 A 123 Figure 24 430751 Drawing files ...
Страница 124: ...124 451253 A Figure 25 871 212984 SBP 29 Installation Manual ...
Страница 125: ...451253 A 125 Figure 26 407070 Drawing files ...
Страница 126: ...126 451253 A Figure 27 448231_1A SBP 29 Installation Manual ...
Страница 127: ...451253 A 127 Figure 28 427512 Drawing files ...
Страница 128: ...128 451253 A Figure 29 435680 SBP 29 Installation Manual ...
Страница 129: ...451253 A 129 Figure 30 444783 Drawing files ...
Страница 151: ......
Страница 152: ... 2019 Kongsberg Maritime ...