OPERATION
EXPLANATION OF COMPONENTS
AIR PRESSURE GAUGE
This gauge (6) indicates the air pressure inside the air tank.
The green range should be lit up during operation.
If the red range lights up during operation, the alarm buzzer will
sound, the central warning lamp will flash, and the air pressure
monitor lamp will also flash at the same time.
If this happens, stop the machine, raise the engine speed, and wait
until the green range lights up.
REMARK
If the air pressure drops further, the parking brake is automatically
applied.
ENGINE WATER TEMPERATURE GAUGE
This gauge (7) indicates the engine cooling water temperature.
The green range should be lighted up during operation.
If the red range lights up during operation, the alarm buzzer will
sound, the central warning lamp will flash, and the engine water
temperature monitor lamp will flash at the same time.
If this happens, stop the machine, run the engine under no load at
a mid-range speed, and wait until the green range lights up.
If the red range lights up, the engine output of the machine
equipped with an electronic governor is automatically limited.
TORQUE CONVERTER OIL TEMPERATURE GAUGE
This gauge (8) indicates the torque converter oil temperature.
The green range should be lit up during operation.
If the red range lights up during operation, the alarm buzzer will
sound, the central warning lamp will flash, and the torque converter
oil temperature monitor lamp will flash at the same time. If this
happens, stop the machine, run the engine under no load at a
mid-range speed, and wait until the green range lights up.
RETARDER OIL TEMPERATURE GAUGE
This gauge (9) indicates the retarder cooling oil temperature.
The green range should be lit up during operation.
If the red range lights up during operation, the alarm buzzer will
sound, the central warning lamp will flash, and the retarder oil
temperature monitor lamp will flash at the same time. If this
happens, stop the machine, run the engine under no load at a
mid-range speed, and wait until the green range lights up.
3 - 19
Содержание HD785-5
Страница 2: ... 1 1 ...
Страница 4: ... FOREWORD FOREWORD 1 3 ...
Страница 5: ... FOREWORD FOREWORD 1 4 ...
Страница 15: ... 2 1 ...
Страница 19: ... SAFETY SAFETY LABELS POSITION FOR ATTACHING SAFETY LABELS 2 5 ...
Страница 47: ... 3 1 ...
Страница 132: ... OPERATION OPERATION Brake performance Downhill distace Continuous Tire size 27 00R49 3 86 ...
Страница 166: ... 4 1 ...
Страница 237: ... 5 1 ...
Страница 239: ... SPECIFICATIONS SPECIFICATIONS 5 3 ...
Страница 240: ... 6 1 ...
Страница 299: ... 7 1 ...
Страница 307: ... HD785 5 DUMP TRUCK Form No PEN00042 03 2006 KOMATSU All Rights Reserved Printed in Japan 04 06 ...