HIGH ALTITUDE SPECIFICATIONS
The hydraulic tank on the high altitude specification machine is pressurized to prevent cavitation of the hydraulic
pump.
This section gives information about parts that are different from the standard specification machine. Any part not
given here is the same as the standard specification machine, so see the manual for the standard specification
machine for details.
EXPLANATION OF COMPONENTS
PRESSURE CAUTION LAMP
This lamp lights up when the pressurizing pressure in the hydraulic
tank goes down. If it lights up, check that the pressurizing valve is
closed and that the pressurizing piping is not is disconnected.
If the body is raised to near the maximum height, the lamp may light
up, but this does not indicate any abnormality.