Kollmorgen
Mounting and Wiring
SILVER
LINE
®
Product Family
4-15
Line Voltage
(120 VAC shown)
Rectifier Bridge
AC
AC
+
-
J1-2
(-)
J1-1
(+)
J1-2
(-)
J1-2
(-)
BJx
#1
BJx
#2
BJx
#3
BJx
#4
Customer Provided Connections
SPS(R)-4008-4
J1-5
(+)
J1-4
(-)
J1-5
(+)
J1-4
(-)
J1-5
(+)
J1-4
(-)
J1-5
(+)
J1-4
(-)
1
2
3
4
5
6
7
8
SPS(R) Terminal Strip Wiring
1 & 4:
AC Line (120 VAC or 240 VAC)
2 & 3:
115/230VAC Select:
For 110VAC: Connect 1-2 and 3-4
For 230VAC: Connect 2-3
5 & 6:
Bus + (4 Connections)
7 & 8:
Bus - (4 Connections)
F1
F2
Note: F1 and F2 are 250V,
1.5 A, 3AG Fuses.
Optional
Regen
Unit
J3-1(+)
J3-4 (-)
1
3 4 5 6 7 8
Each terminal has 4 “Insertion
Points” which are all electrically
connected. The bottom two are
provided for CUSTOMER
connections. The top two are
reserved for factory connections.
Do not insert more than one wire in
each point.
2
Two FACTORY
“insertion points.”
Two CUSTOMER
“insertion points.”
Figure 4-1 SPS/R-4008-4 Field Wiring with Detail of Terminal Strip
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com