15 Setup
15.1 Important notes
Only specialist personnel with extensive knowledge in the areas of electrical engineering /
drive technology are allowed to commission the drive unit of drive and motor.
Deadly voltages can occur, up to 900V. Risk of electric shock! Check that
all live connection points are safe against accidental contact.
Never undo the electrical connections to the motor when it is live. Risk of
electric shock! The residual charge in the capacitors of the drive can
produce dangerous voltages up to 10 minutes after the mains supply has
been switched off. Even when the motor is not rotating, control and power
leads may be live. Measure the DC-link voltage and wait until it has fallen
below 60V.
The surface temperature of the motor can exceed 100°C in operation.
Danger of light burns! Check (measure) the temperature of the motor.
Wait until the motor has cooled down below 40°C before touching it.
The drive performing unplanned movements during commissioning can-
not be ruled out.
Make sure that, even if the drive starts to move unintentionally, no danger
can result for personnel or machinery. The measures you must take in
this regard for your task are based on the risk assessment of the appli-
cation.
AKMH Installation | Table of Contents
Kollmorgen | March 2014
51
Содержание AKMH2
Страница 62: ...18 4 Dimensions AKMH3 Ax flanges AKMH Installation Table of Contents 62 Kollmorgen March 2014...
Страница 64: ...18 7 Dimensions AKMH4 Ax flanges AKMH Installation Table of Contents 64 Kollmorgen March 2014...
Страница 66: ...18 10 Dimensions AKMH5 Ax flanges AKMH Installation Table of Contents 66 Kollmorgen March 2014...
Страница 68: ...18 13 Dimensions AKMH6 Ax flanges AKMH Installation Table of Contents 68 Kollmorgen March 2014...
Страница 71: ...19 3 Hygienic Standards Declaration of Conformity AKMH Installation Table of Contents Kollmorgen March 2014 71...
Страница 73: ...AKMH Installation Kollmorgen March 2014 73...
Страница 74: ...74 Kollmorgen March 2014 AKMH Installation...