www.kolidainstrument.com
31
PROCEDURE
Operating Procedure
Operation
Display
1) Press 0SET on the first page of the “MEAS
Mode Screen”.
It asks “0SET H Angle?”
0SET
MEAS(1/3)
0SET H Angle
?
YES NO
2)
Press F3 YES, the horizontal angle of the
collimation direction is set to 0°00′00″.
Press F3
YES
MEAS(1/3)
SHV
S
H
V
VA 273
°
18
′
15
″
HAR 0
°
00
′
00
″
DIST D/C 0SET HSET
8.1.1 Example Measuring the Horizontal Angle between Two Points
(1) (2)
PROCEDURE
Operating Procedure
Operation
Display
1)
Using the horizontal clamp and the horizontal
tangent screw, sight the backsight point. From the
MEAS mode, page 1 menu, press 0SET, then press
YES , set the back sight direction to 0.
0SET
+
F3
MEAS(1/3)
SHV
S
H
V
VA 0
°
00
′
00
″
HAR 0
°
00
′
00
″
DIST D/C 0SET HSET
2)
Sight the foresight point, the displayed (HAR)
value is the included angle between 2 points.
Sight
Foresight
Point
MEAS(1/3)
SHV
S
H
V
VA 0
°
00
′
00
″
HAR 60
°
00
′
21
″
DIST D/C 0SET HSET