www.kolidainstrument.com
183
3) Distance and angle setting-out data input command ( /Db)
/Db -123.456, 359.5959[,SUM]CRLF
The format is same as input command Db.
4) Horizontal angle input command ( /Dc)
/Dc 359.5959[,SUM]CRLF
a b
a)
Data identification code
b)
Horizontal angle value
5
)
Backsight coordinate input command ( /Dd)
/Dd 123.456, _123.456, _999.999[,SUM]CRLF
The format is same as input command Dd.
Note: the order of East and North coordinate will not be changed according to instrument setting
6
)
Instrument height, target height, temperature, pressure input command ( /De)
/De 12.345, 1.500, -20, 1015[,SUN]CRLF
a b c d e
a)
Data identification code
b)
Instrument height
c)
Target height
d)
Temperature value
e)
Air pressure value
7) Coordinate setting-out data input command ( /Df)
/Df 1234.567, _12.34, 9.182[,SUM]CRLF
The format is same as input command Df.
8) Coordinate data input commands ( /Dg)
/Dg 123.456, -1234.123, 12.345, 12345678, CODE[,SUM]CRLF
a b c d e f
a) Data identification code
b) N coordinate
c) E coordinate
d) Z coordinate
e) Point number
f) Code
Note: the order of East and North coordinate will not be changed according to instrument setting