![Koki Holdings NR 3665DA Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/koki-holdings/nr-3665da/nr-3665da_service-manual_1990322024.webp)
-23-
Fig. 29
Fig. 30
• Check that the wires are not caught and there is no clearance between housings (A) and (B) when putting
them together.
• After reassembly, check that the terminal of the Wiring Ass’y
[60]
is properly mounted without mismatch
and it is slightly movable as shown in Fig. 30. Then, mount the battery to Housing (D).(E).(F) Ass’y
[51]
and pull it in “Y” direction as shown in Fig. 30 to check that the clearance between the Housing Ass’y
[50]
and Housing (D).(E).(F) Ass’y
[51]
is 3 to 4 mm.
[50]
Clearance: 3 to 4 mm
[51]
Y direction
[60]