background image

20

RAC Assembly (will vary 

depending on model)

Hose Washer

Flow 

Regulator

Hose

Mira Minilite BIV

A  12  L/Min  flow  regulator  (natural)  is  supplied 

separately in the component pack, designed to 

be  fitted  between  the  shower  hose  and  RAC 

assembly.

Mira Miniduo BIV, Pace BIV 

A  12  L/Min  flow  regulator  (natural)  is  supplied 

separately in the component pack, designed to 

be  fitted  between  the  shower  hose  and  RAC 

assembly.

Mira Miniduo with Eco Showerhead BIV

A 7.0 L/Min flow regulator (olive green) is supplied 

separately in the component pack, designed to 

be  fitted  between  the  shower  hose  and  RAC 

assembly.

Содержание Mira Miniduo

Страница 1: ...ace Mira Minilite and Mira Miniduo including Eco Models Thermostatic Mixers These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS Please call us on 084...

Страница 2: ...on off and temperature control The Mira Pace Mira Pace with Eco Showerhead Mira Pace with Adjustable Inlet Elbows Mira Miniduo and Mira Miniduo with Eco Showerhead are thermostatic mixers with separa...

Страница 3: ...ratedand maintained in accordance with manufacturer s recommendations 2 Type 2 Valves are only used for applications covered by their approved designations refer to the TMV2 Requirements Manual 3 Peri...

Страница 4: ...Template q 1 x TMV2 Requirements Manual Component Pack q 2 x Concealing Plates q 2 x Compression Nuts q 2 x Olives q 2 x Wall Plugs q 2 x Fixing Screws q 1 x 2 5 mm Hexagonal Key Mira Minilite EV or M...

Страница 5: ...bly Documentation q 1 x Guarantee Registration Document q 1 x Cardboard Building in Shroud q 1 x TMV2 Requirements Manual q 1 x O Key q 1 x Flow Regulator refer to section Flow Regulators q 1 x RAC As...

Страница 6: ...h Eco Showerhead 7 0 L Min Olive Green Supplied in the component pack designed to be fitted between the shower hose and shower valve outlet Miniduo with Eco Showerhead EV L98B with Eco Showerhead 7 0...

Страница 7: ...mperatures for short periods without damage however this could detrimentally affect thermostatic performance For safety and performance reasons it is recommended that the maximum hot water temperature...

Страница 8: ...d Pace with Adjustable Elbows 46 76 5 133 153 Pipe Centres at extremes of elbow adjustment Pace Pace with Eco Showerhead Miniduo and Miniduo with Eco Showerhead EV Note If you are retro fitting your m...

Страница 9: ...conducted by designated qualified and competent personnel The installation must comply with the Water Supply Regulations 1999 Water Fittings or any particular regulations and practices specified by t...

Страница 10: ...nished wall at 110 mm centres Note If you are retro fitting your mixing valve onto existing pipework an Adjustable Elbow Pack is available if required refer to section Accessories 39 mm 3 For solid wa...

Страница 11: ...gulator from the outlet nipple first d Refit the sealing plug and outlet nipple in the opposite outlets and tighten Note Make sure that the O seals are correctly fitted Note On Mira Minilite Eco model...

Страница 12: ...d fit onto the backplate Important Make sure that the hot and cold inlets on the mixer correspond with the hot and cold inlet supplies 13 Tighten the compression nuts onto the mixer with a suitable wr...

Страница 13: ...k and using the adjustable backplate as a template mark the position of the adjustable backplate fixing holes 7 For solid walls drill the holes for the backplate with a 6 mm drill and insert the wall...

Страница 14: ...the BIV shower fittings it is recommended that the outlet be positioned to one side of the mixer This is to prevent the flexible hose from obstructing the shower controls refer to illustration 103 mm...

Страница 15: ...he position of the mixer and draw around the inside of the concealing ring 8 Carefully cut away the plasterboard and or brick work to a depth of between 56 and 76 mm from the finished wall surface Imp...

Страница 16: ...e stud partition Screws Outlet Pipe to Fittings Hot Supply Cold Supply 40 mm RAC Wallplate 14 Turn on the water supplies and check for leaks 15 Determine the finished wall position e g tile thickness...

Страница 17: ...e wall 26 Fit the two wall plugs supplied and secure the wallplate to the wall with the two wallplate screws 27 Make sure that there is clearance behind the wallplate and temporarily fit the two backp...

Страница 18: ...the lugs on the backplate 35 Fit the concealing ring over the mixer and mark the positions of the three fixing holes 36 For solid walls drill three 6 mm holes for the wall plugs For other types of wal...

Страница 19: ...19 Mira Minilite EV Mira Minilite Eco EV Mira Moto EV...

Страница 20: ...d between the shower hose and RAC assembly Mira Miniduo BIV Pace BIV A 12 L Min flow regulator natural is supplied separately in the component pack designed to be fitted between the shower hose and RA...

Страница 21: ...21...

Страница 22: ...es anti clockwise in the following sequence Off On Cold Warm Maximum Preset Temperature Mira Pace Mira Pace with Eco Showerhead Mira Miniduo and Mira Miniduo with Eco Showerhead thermostatic mixers ha...

Страница 23: ...For Type 2 installations the maximum blend temperature is determined by the application refer to the TMV2 Requirements Manual 1 Turn on the mixer to the maximum temperature and maximum flow i e fully...

Страница 24: ...let 4 Using a suitably sized wrench loosen both compression nuts 5 Using a 2 5 mm hexagonal key supplied unscrew the grubscrews securing the mixer to the backplate 6 Remove the mixer 7 The filters are...

Страница 25: ...crew the grubscrew using a 2 5 mm hexagonal key supplied and pull off the control knob s 5 Carefully unclip and remove the concealing plate from the backplate Note Use a screwdriver in the cutout to a...

Страница 26: ...B 1663 155 Filter Pack x2 1663 159 Seal Pack components identified A 1663 161 Component Pack components identified B 1663 162 Screw Pack components identified C 1663 265 Flow Regulator Pack containin...

Страница 27: ...27...

Страница 28: ...082138 W2 N 1663 1694 B94A D Kohler Mira Limited October 2013 Guarantee This guarantee is in addition to your statutory rights and is subject to the following conditions Note The guarantee does not co...

Отзывы: