background image

2

CONTENTS

Introduction 2

Type 2 Valves 

2

Guarantee 3
Recommended Usage 

3

Patents and Design Registration 

3

Safety Warnings 

3

Pack Contents 

4

Exposed Thermostatic Mixers 

4

Built-in Thermostatic Mixers 

5

Valve Combinations 

6

Specifications 

7

Installation  

9

Suitable Plumbing Systems 

9

General 9
Exposed Thermostatic Mixers 

10

Adjustable Elbow Installation 

13

Flow Regulators 

19

Operation 22
Commissioning 23

Maximum Temperature Setting 

23

Fault Diagnosis 

24

User Maintenance 

24

Filter Replacement 

24

Lubricants 25
Cleaning 25

Accessories 25
Spare Parts 

26

If you experience any difficulty with the 

installation or operation of your new 

thermostatic mixer, please refer to 

‘Fault 

Diagnosis’

, before contacting Kohler Mira Ltd. 

Our contact details can be found on the back 

cover of this guide.

INTRODUCTION

Thank you for purchasing a quality Mira product. To 

enjoy the full potential of your new product, please 

take time to read this guide thoroughly, having 

done so, keep it handy for future reference.

The Mira Moto, Mira Minilite and Mira Minilite Eco 

are thermostatic mixers with a single control lever 

for on/off and temperature control.

The Mira Pace, Mira Pace with Eco Showerhead, 

Mira Pace with Adjustable Inlet Elbows, Mira 

Miniduo and Mira Miniduo with Eco Showerhead 

are thermostatic mixers with separate on/off and 

temperature controls.

The thermostatic mixers incorporate a wax 

capsule temperature sensing unit, which provides 

an almost immediate response to changes in 

pressures or temperature of the incoming water 

supplies to maintain the selected temperature. An 

adjustable maximum temperature stop is provided 

which limits the temperature to a safe level. 

Inlet filters are fitted to protect the thermostatic 

cartridge.

Type 2 Valves

These  products  have  been  certified  as Type 2 

valves under the BUILDCERT TMV2 scheme. 

They also comply with the Water Supply (water 

fittings) Regulations 1999.

For Type 2 Valves refer to the TMV2 Requirements 

Manual.

Application

The approved designations for Type 2 Valves 

are as follows:

Models

Designation

Moto, Minilite

LP-S, HP-S, HP-SE

#

the economy designation is achieved with the 

fitting of the outlet flow regulator.

Models

Designation

Pace, Miniduo

LP-S, HP-S

Important! The fitting of any flow regulator to 

Pace or Miniduo models will invalidate TMV2 

compliance  due  to  the  minimum  flow  rate 

requirements.  Do  not  fit  flow  regulators  in 

TMV2 applications to these models.

Содержание Mira Miniduo

Страница 1: ...ace Mira Minilite and Mira Miniduo including Eco Models Thermostatic Mixers These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS Please call us on 084...

Страница 2: ...on off and temperature control The Mira Pace Mira Pace with Eco Showerhead Mira Pace with Adjustable Inlet Elbows Mira Miniduo and Mira Miniduo with Eco Showerhead are thermostatic mixers with separa...

Страница 3: ...ratedand maintained in accordance with manufacturer s recommendations 2 Type 2 Valves are only used for applications covered by their approved designations refer to the TMV2 Requirements Manual 3 Peri...

Страница 4: ...Template q 1 x TMV2 Requirements Manual Component Pack q 2 x Concealing Plates q 2 x Compression Nuts q 2 x Olives q 2 x Wall Plugs q 2 x Fixing Screws q 1 x 2 5 mm Hexagonal Key Mira Minilite EV or M...

Страница 5: ...bly Documentation q 1 x Guarantee Registration Document q 1 x Cardboard Building in Shroud q 1 x TMV2 Requirements Manual q 1 x O Key q 1 x Flow Regulator refer to section Flow Regulators q 1 x RAC As...

Страница 6: ...h Eco Showerhead 7 0 L Min Olive Green Supplied in the component pack designed to be fitted between the shower hose and shower valve outlet Miniduo with Eco Showerhead EV L98B with Eco Showerhead 7 0...

Страница 7: ...mperatures for short periods without damage however this could detrimentally affect thermostatic performance For safety and performance reasons it is recommended that the maximum hot water temperature...

Страница 8: ...d Pace with Adjustable Elbows 46 76 5 133 153 Pipe Centres at extremes of elbow adjustment Pace Pace with Eco Showerhead Miniduo and Miniduo with Eco Showerhead EV Note If you are retro fitting your m...

Страница 9: ...conducted by designated qualified and competent personnel The installation must comply with the Water Supply Regulations 1999 Water Fittings or any particular regulations and practices specified by t...

Страница 10: ...nished wall at 110 mm centres Note If you are retro fitting your mixing valve onto existing pipework an Adjustable Elbow Pack is available if required refer to section Accessories 39 mm 3 For solid wa...

Страница 11: ...gulator from the outlet nipple first d Refit the sealing plug and outlet nipple in the opposite outlets and tighten Note Make sure that the O seals are correctly fitted Note On Mira Minilite Eco model...

Страница 12: ...d fit onto the backplate Important Make sure that the hot and cold inlets on the mixer correspond with the hot and cold inlet supplies 13 Tighten the compression nuts onto the mixer with a suitable wr...

Страница 13: ...k and using the adjustable backplate as a template mark the position of the adjustable backplate fixing holes 7 For solid walls drill the holes for the backplate with a 6 mm drill and insert the wall...

Страница 14: ...the BIV shower fittings it is recommended that the outlet be positioned to one side of the mixer This is to prevent the flexible hose from obstructing the shower controls refer to illustration 103 mm...

Страница 15: ...he position of the mixer and draw around the inside of the concealing ring 8 Carefully cut away the plasterboard and or brick work to a depth of between 56 and 76 mm from the finished wall surface Imp...

Страница 16: ...e stud partition Screws Outlet Pipe to Fittings Hot Supply Cold Supply 40 mm RAC Wallplate 14 Turn on the water supplies and check for leaks 15 Determine the finished wall position e g tile thickness...

Страница 17: ...e wall 26 Fit the two wall plugs supplied and secure the wallplate to the wall with the two wallplate screws 27 Make sure that there is clearance behind the wallplate and temporarily fit the two backp...

Страница 18: ...the lugs on the backplate 35 Fit the concealing ring over the mixer and mark the positions of the three fixing holes 36 For solid walls drill three 6 mm holes for the wall plugs For other types of wal...

Страница 19: ...19 Mira Minilite EV Mira Minilite Eco EV Mira Moto EV...

Страница 20: ...d between the shower hose and RAC assembly Mira Miniduo BIV Pace BIV A 12 L Min flow regulator natural is supplied separately in the component pack designed to be fitted between the shower hose and RA...

Страница 21: ...21...

Страница 22: ...es anti clockwise in the following sequence Off On Cold Warm Maximum Preset Temperature Mira Pace Mira Pace with Eco Showerhead Mira Miniduo and Mira Miniduo with Eco Showerhead thermostatic mixers ha...

Страница 23: ...For Type 2 installations the maximum blend temperature is determined by the application refer to the TMV2 Requirements Manual 1 Turn on the mixer to the maximum temperature and maximum flow i e fully...

Страница 24: ...let 4 Using a suitably sized wrench loosen both compression nuts 5 Using a 2 5 mm hexagonal key supplied unscrew the grubscrews securing the mixer to the backplate 6 Remove the mixer 7 The filters are...

Страница 25: ...crew the grubscrew using a 2 5 mm hexagonal key supplied and pull off the control knob s 5 Carefully unclip and remove the concealing plate from the backplate Note Use a screwdriver in the cutout to a...

Страница 26: ...B 1663 155 Filter Pack x2 1663 159 Seal Pack components identified A 1663 161 Component Pack components identified B 1663 162 Screw Pack components identified C 1663 265 Flow Regulator Pack containin...

Страница 27: ...27...

Страница 28: ...082138 W2 N 1663 1694 B94A D Kohler Mira Limited October 2013 Guarantee This guarantee is in addition to your statutory rights and is subject to the following conditions Note The guarantee does not co...

Отзывы: