12
1333238-W2-A
Installing the Shower Fittings
1.
Fit the hose retaining ring and clamp bracket to the middle bar, then screw all
three bars together.
2.
Fit the wall bracket into the riser arm with the grub screw at the top.
3.
Make sure that the lower bar is pushed fully into the valve to engage the seal.
Failure to do so will position the wall bracket incorrectly and may result in a
leak from around the outlet of the valve.
4.
Mark holes for the vertical wall fixing bracket. Use the riser arm assembly as
a guide and ensure it is vertical.
5.
Remove assembled bar and fixing bracket.
6.
Drill the holes for the wall fixing bracket. Fit the wall plugs and fix the bracket
to the wall using the screws supplied.
7.
Refit the bar into the shower unit and loosely fit the concealing cover to the
riser arm. Ensure lower bar is fitted correctly as shown in diagram below.
8.
Fit the riser arm onto the wall fixing bracket and tighten the grubscrew with a
2.5 mm hex key. Fit the concealing cover over the bracket.
9.
Tighten the grubscrew at the rear of the shower unit to secure the bar using
the 1.5 mm hexagonal wrench. Fit the plug.
10.
Fit the overhead spray.
Note!
A flow regulator (not supplied) may be required for installation on high
pressure systems (above 0.5bar).
11.
Fit the shower hose through the hose retaining ring and connect to both the
shower unit and the showerhead. Connect the conical with red cover or white
label to the showerhead.
Содержание Mira Honesty
Страница 2: ...2 1333238 W2 A...