Fault Diagnosis
Symptom
Cause / Rectification
Water too hot or
too cold
Inlets reversed (hot supply to cold inlet of shower unit),
rework inlet pipework.
Check the washer / filters are not blocked.
Check the maximum temperature setting (If you have a
combination type boiler it may not be producing sufficient
hot water at the desired flow rate). Fit a flow regulator to the
outlet of the shower unit.
Installation conditions outside operating parameters, refer
to
‘Specifications’
and
‘Commissioning’
.
Poor temperature
control
Make sure that the inlet temperature differentials are
sufficient, refer to
‘Specifications’
.
Fluctuating or
reduced flow
Check the showerhead and hose are not blocked.
Check the washer / filters are not blocked.
Make sure that the maintained inlet pressures are nominally
balanced and sufficient, refer to
‘Specifications’
.
Air lock or partial blockage in the pipework.
Water leaking from
the showerhead
Water may drain from the showerhead for a short period
after showering, this is normal.
Water leaking from
the hose on the bar
valve
Check that the lower riser bar is fully located in the top of
the bar valve.
Check the hose washer is fitted and conical nut fully
tightened.