28
1486928-W2-A
WARNING!
There are no user serviceable parts inside the shower.
Servicing of the shower must only be carried out by qualified,
competent personnel following the instructions provided in this
guide and those provided with any spare part.
Before replacing any parts, ensure that the underlying cause of
the malfunction has been resolved.
Cleaning the Inlet Filter
Warning!
Isolate the electrical and water
supplies before removing the cover.
Remove the cover.
Remove the elbow from the inlet connector.
Note:
Depending on your installation it may be
necessary to remove the shower from the wall
to allow filter removal.
In this case isolate all supplies and follow steps
4 - 6 in reverse order as detailed in section:
‘INSTALLATION’
.
Prise the filter from the inlet connector assembly.
Rinse the filter under a running tap to remove
any lodged particles. If necessary, use a kettle
descalent in accordance with the manufacturer’s
instructions.
Refit the inlet filter and follow steps 6 - 9 as
described in section:
‘INSTALLATION’.
Note:
If the shower was removed from the wall,
steps 4, 5, 6, 8 and 9 will need to be followed as
described in section:
‘INSTALLATION’.
Follow the steps detailed in section:
‘COMMISSIONING’
to prepare the shower for
use.
Servicing
Inlet Filter
Inlet Connector