11
1486928-W2-A
1. The plumbing installation must comply with all national or local water regulations
and all relevant building regulations, or any particular regulation or practice
specified by the local water supply company.
2.
DO NOT
use sealing compounds on any pipe fitting or joints.
3.
DO NOT
install the product in a position in which service access is limited.
4. Decide on a suitable position for the shower (minimum distance of 200 mm from
the ceiling to allow for cover fit and removal).
5. The shower is suitable for installation within the shower area and is fitted with a
pressure relief valve. It must be positioned over a water catchment area with the
controls at a convenient height for the user.
6. The shower must be fitted to a waterproof flat and even wall surface.
7.
DO NOT
fit the shower to the wall and tile up to the case.
8.
DO NOT
seal the gap between the shower and the wall surface.
9. The showerhead should be positioned so that it discharges down the centre line
of the bath or across the opening of a shower cubicle.
10. The showerhead must be directed away from the shower unit, during normal use
the showerhead must not spray directly on to the shower unit.
11.
DO NOT
apply excessive force to plumbing connections; always provide
mechanical support when making plumbing connections. Any soldered joints
should be made before connecting the shower.
12. This shower is not designed to be plumbed directly from the rear. For rear-entry
supply, add an elbow to the supply pipe and connect as a rising or a falling supply.
13. If pipework and/or electrical cables enter the shower from the rear through a hole
in the wall provision must be made to prevent water ingress back into the wall
structure.
14. This shower is intended to be permanently connected to the mains water supply,
only use the inlet connection supplied with the shower.
DO NOT
use any other type of fitting.
15. A full bore/non restrictive servicing valve must be fitted in a readily accessible
position adjacent to the shower to facilitate maintenance of the shower.
DO NOT
use a valve with a loose washer plate (jumper) as this can lead to a build up of
static pressure.
16. A water treatment device should be installed where the water hardness may
exceed 200 ppm. Malfunctions caused by excessive limescale formation are not
covered by this shower’s guarantee (see back page for details).
17. The installation must not cause the hose to be sharply kinked during normal use.
18.
DO NOT
perform the electrical installation until the plumbing has been completed
and checked for leaks.